Trending data – Banner SureCross DX80 Wireless Networks User Manual
Page 73

The screen shots shows a sample weekly event occurring Monday through Friday, excepting the specific holidays listed on the right. This
event starts at 6:00 am and ends at 8:00 pm and writes a value of 0 during that time to register 121. During the off times, a value of 1 is
written to register 121.
Register 121 controls an automated lock for the front door of a business that is typically open Monday through Friday from 6:00 am until
8:00 pm. These doors remain locked on Saturdays, Sundays, and any holiday in the list to the right occurring on the selected days.
An On Demand event is set up similarly, except that it occurs only once on a specified date.
Trending Data
Trending data calculates average, low, and high values within a specified time period. Use the System > Action Rules > Trending tab to
set up statistical tracking of specific registers.
SureCross Web Configurator
rev. -
www.bannerengineering.com - tel: 763-544-3164
73
- SureCross DX80 Wireless Networks (11 pages)
- SureCross DX80 FlexPower Nodes with Analog I/O (4 pages)
- SureCross DX80 FlexPower Nodes with Analog I/O (114 pages)
- SureCross DX80 FlexPower Nodes with Analog I/O (9 pages)
- SureCross DX80 Wireless Networks (4 pages)
- SureCross DX80 FlexPower Nodes with Analog I/O (11 pages)
- SureCross DX80 Wireless Networks (10 pages)
- SureCross DX80 Wireless Networks (7 pages)
- SureCross DX80 FlexPower Nodes with Analog I/O (10 pages)
- SureCross DX80 Nodes with Analog I/O (10-30V dc) (9 pages)
- SureCross DX80 Wireless Networks (43 pages)
- SureCross DX80 FlexPower Nodes with Analog I/O (8 pages)
- SureCross DX80 Nodes with Analog I/O (10-30V dc) (8 pages)
- SureCross DX80 FlexPower Nodes with Analog I/O (2 pages)
- SureCross DX80 Wireless Networks (8 pages)
- SureCross DX80 FlexPower Nodes with Analog I/O (12 pages)
- SureCross DX80 Wireless Networks (9 pages)
- SureCross DX80 Wireless Networks (5 pages)
- SureCross DX80 Wireless Networks (12 pages)
- SureCross DX80 Wireless Networks (107 pages)
- SureCross DX80 FlexPower Nodes with Analog I/O (31 pages)
- SureCross DX80 FlexPower Nodes with Analog I/O (7 pages)
- SureCross DX80 Wireless Networks (3 pages)
- EZ-SCREEN Safety Light Curtain Systems (4 pages)
- EZ-SCREEN Safety Light Curtain Systems (71 pages)
- EZ-SCREEN Safety Light Curtain Systems (74 pages)
- EZ-SCREEN Safety Light Curtain Systems (60 pages)
- EZ-SCREEN Low-Profile Safety Light Curtain Systems (76 pages)
- EZ-SCREEN Safety Light Curtain Systems (64 pages)
- EZ-SCREEN Safety Light Curtain Systems (4 pages)
- EZ-SCREEN Safety Light Curtain Systems (2 pages)
- EZ-SCREEN Safety Light Curtain Systems (16 pages)
- U-GAGE T30U—Pump Control (8 pages)
- U-GAGE T30U—Pump Control (7 pages)
- U-GAGE T30U—Pump Control (12 pages)
- U-GAGE T30U—Pump Control (2 pages)
- D10—Discrete (4 pages)
- WORLD-BEAM QS18 Universal Voltage (7 pages)
- SI-HG63 Hinge Style Switches (8 pages)
- SI-HG63 Hinge Style Switches (7 pages)
- SI-HG63 Hinge Style Switches (14 pages)
- SureCross DX85 Expandable Remote I/O (10 pages)
- SureCross DX85 Expandable Remote I/O (9 pages)
- SM30 High-Power Series (4 pages)