Chapter 6 general operation, Setting a limit line, Figure 46 setting a limit line – Bird Technologies SA-6000XT-Manual User Manual
Page 67: Measurement hold, Setting a limit line measurement hold
51
Chapter 6
General Operation
Setting a Limit Line
1.
While in the Measure Match mode or the Fault Location mode, press the
Limit Test key:
First press - Test ON Aud (line and sound)
Second press - Test ON (line only)
Third press - Test OFF
2.
Press the Config key.
3.
Press the Limit Line softkey.
4.
Use the keyboard to enter a limit value of the choice or use the suggested
limits listed below (use the +/- key to enter a negative value) then press the
Enter key.
Antenna at resonance - 14 dB
Connectors - 25 dB
Jumpers - 35 dB
Lightning protector - 25 dB
Transmission lines - 30 dB
5.
Press the Esc key to exit the configure screen
Figure 46 Setting a Limit Line
Measurement Hold
Measurement Hold stops updating the display at the end of the current sweep.
Press the Hold key to toggle the sweep hold off and on. A measurement is held
when there is a lock icon in the indicator ball. Measurement hold is available in Mea-
sure Match mode and Fault Location mode.
1.
Press the Hold softkey to hold the measurement.
2.
Press the Run softkey to resume sweeping.
3.
The lock symbol indicates that the measurement is held.