85

Transit Drop

10 drops on corners and faces per MIL-PRF-
28800F, Class 2

Bench Handling

4 drops on each face per MIL-PRF-28800F, Class 2

Vibration

Random 10 to 500 Hz per MIL-PRF-28800F, Class 2

Shock, Functional

30 G half-sine shock pulse per MIL-PRF-28800F,
Class 2

RoHS Compliance

Components & assembly must meet European RoHS
Directive 2002/95/EC, without utilizing exemption.

CE Compliance

EN 61326-1-2:2006 Electrical equipment for
measurement and control use.
EMC 61010-1:2001 - Safety
89/336/EEC - EMC
73/23/EEC and Amendment 93/68/EEC - Low Voltage

Fungus Resistance

5 species for 28 days at 30°C and 95% humidity per
MIL-PRF-28800F, Class 2

Calibration Cycle

User Defined

Calibration/Measurement

SOL cal only (calibration can be saved and
recalled, user must ensure that cal is still valid

MTBF

Designed for 10 years MTBF

Firmware Updating

Field firmware updated via USB port.

Upgradability

The SA-3600XT is field upgradable to the SA-6000XT

Languages

English

Serviceability

Only serviceable in an approved Bird Service
Center.

Markers and Limits

6 markers, 1 flat limit line