Power measure mode, General, Function – Bird Technologies SA-6000XT-Manual User Manual
Page 100
84
Power Measure Mode
General
Function
Displays readings from Power Sensors
Specifications
Determined by sensor.
Sensor Detection
Automatically detect which sensor is connected
and display the appropriate measurement screen.
Model Numbers
SA-3600XT (25 to 3600 MHZ)
SA-6000XT (25 to 6000 MHZ)
Data Storage
Internal
64 Mb storage
capable of:
238 point traces
475 point traces
949 point traces
External
2,500
1,250
650
USB drive
Display
5.7” QVGA, Color with backlight, Indoor/Outdoor
viewable, sunlight readable
General Display
Requirements
Include all functionality of existing SA product
IFBW
Fixed
Interconnects / Interfaces
Antenna
Sensor
PC
N (F)
USB 2.0 Type A
USB 2.0 Type B
Power Requirements
Internal
External DC
External AC
Lithium-ion rechargeable battery
5 hours minimum operating time
9 to 16 VDC, < 3 A
90 to 264 VAC @ 45 to 66 Hz, AC/DC adapter
required
Housing
PC/ABS housing, color is the same as existing SA-
6000EX for both models.
Dimensions, Nominal
10.5” x 8.4” x 3.3”
Weight, Max
5.05 lbs.
Environmental
Specifications
Operating Temp
Storage Temp
Battery Charging Temp
Humidity
Altitude
– 10 to +50°C (14 to 122°F)
– 40 to +80°C (– 40 to +176°F)
0° to +35° C (32° to 95° F)
95% maximum (non-condensing)
15,000 feet (4,500 m) max
Drop Test
1 meter drop in most severe position per EN 61010-1