11 to 16 – Rockwell Automation FlexPak/WebPak 3000 DC Drive AutoMax Network Communication Board User Manual
Page 74

7-
6
Aut
o
Max
Net
w
or
k Comm
unicat
ion
O
p
tion
B
oard
11
TB Tension On
12
TB Current Memory
13
TB Underwind
14
TB Slack Take Up
15
Level Det1 Output
2
SPD
LOOP
REFERENCE
(P.295)
Final speed/voltage loop reference value
3
SPD
LOOP
FEEDBACK
(P.296)
Final speed/voltage loop feedback value after all scaling
4
SPD
LOOP
OUTPUT
(P.299)
Speed loop
PI
block output value
4095 at
MAXIMUM
CURRENT
(P.007)
5
ARMATURE
VOLTAGE
(P.289)
Armature voltage feedback value
4095 at
MOTOR
RATED
ARM
VOLTS
(P.009)
6
CML
REFERENCE
(P.196)
Amplitude-and rate-limited value of the selected
CML
reference
7
Average
CML
feedback
CML
feedback average over eight
CML
scans
4095 at
MAXIMUM
CURRENT
(P.007)
8
Network Output Register 1
Value of the parameter selected by
NETW
OUT
REG
1
SELECT
(P.902)
If no valid parameter value selected,
0=
MOTOR
SPEED
IN
RPM
9
Network Output Register 2
Value of the parameter selected by
NETW
OUT
REG
2
SELECT
(P.903)
If no valid parameter value selected,
0=armature voltage in volts
10
Network Output Register 3
Value of the parameter selected by
NETW
OUT
REG
3
SELECT
(P.904)
If no valid parameter value selected,
0=armature current in amps*10 or amps
11 to 16
Tunable, Configurable and Status Data
See table 7.4 on page 7-7.
17
LINE
SPEED
(P.188)
Analog reference value output by the drive
18
DIAMETER
/
TAPER
IN
TP
(P.192)
Diameter/taper range input (TB 16, 17, 18) in counts
after gain and zero applied
DIAMETER
,
TAPER
RANGE
19
TENSION
SETPOINT
IN
(P.492)
Digital value of the tension setpoint input (TB 50, 51)
after gain and zero applied
20
TENSION
/
DANCER
FDBK
(P.493)
Digital value of the tension/dancer feedback input (TB
52, 53) after gain and zero applied
21
FREQ
IN
(P.491)
Frequency input value (terminals 39, 40, 41 on I/O
Expansion board) after all scaling
4095 at full scale
22
OCL
OUTPUT
(P.848)
Outer control loop output value
RPM
23
OCL
PARALLEL
OUT
(P.816)
Output of the selected outer control loop for parallel
mode
Table 7.3 – WebPak 3000 Register Map, Drop_1: Master Read Registers, BASIC and FULL Connections. Runtime Signal Data (Drive Output Data) (Continued)
Register
Bit
Parameter Name (Number)
Description
Settings
Runtime signal data are updated by the regulator every 10 msec.