Rockwell Automation FlexPak/WebPak 3000 DC Drive AutoMax Network Communication Board User Manual
Page 35

F
lex
Pak
3000 Drives
: O
rig
inal Regist
er
M
a
p
5-
5
18
MINIMUM
SPEED
(P.003)
Lowest operating speed
RPM
19
MAXIMUM
SPEED
(P.004)
Highest operating speed
RPM
20
POSITIVE
CURRENT
LIM
(P.005)
Highest amount of current for the forward bridge
% of
MOTOR
RATED
ARM
AMPS
(P.008)
21
NEGATIVE
CURRENT
LIM
(P.006)
Highest amount of current for reverse bridge
% of
MOTOR
RATED
ARM
AMPS
(P.008)
22
TRIM
RANGE
(P.109)
Amount the trim reference will affect the drive reference
%
23
SPD
LOOP
PI
PROP
GAIN
(P.211)
Speed loop
PI
proportional gain
gain * 100
24
SPD
LOOP
PI
LEAD
FREQ
(P.212)
Speed loop
PI
block lead break frequency
radians/second * 100
25
CML
PI
PROP
GAIN
(P.301)
CML
PI
proportional gain
gain * 1000
26
CML
PI
LEAD
FREQUENCY
(P.302)
CML
PI
lead break frequency
radians/second
27
CML
REF
RATE
LIMIT
(P.303)
Min. time for
CML
ref. to go from zero to
MAXIMUM
CURRENT
milliseconds
28
0
NETW
CONNECT
TYPE
(P.910)
AutoMax network connection type
0=
BASIC
; 1=
FULL
8
NETW
REGISTER
MAP
SEL
(P.914)
Network register map selected
0=
ORIGINAL
; 1=
ALTERNATE
29
NETW
COMM
LOSS
SELECT
(P.901)
How the drive responds to network communication loss
0=
FAULT
; 1=
USE
LAST
REF
; 2=
USE
TRMBLK
REF
, 3=
USE
TRMBLK
CNTL
30
AMX
NETW
REF
SELECT
(P.911)
AutoMax network reference selection
0=
DIRECT
; 1 to 8=
BROADCAST
1 to 8
31
REGULATOR
SW
VERSION
(P.794)
Regulator board software version
Table 5.3 – FlexPak 3000 Original Register Map, Drop_1: Master Read Registers, BASIC and FULL Connections. Tunable, Configurable, and Status Data (Drive Output Data) (Continued)
Register
Bit
Parameter Name (Number)
Description
Settings
Tunable, configurable, and status data are updated by the regulator approximately every 600 msec.