6-
14
Aut
o
Max
Net
w
or
k Comm
unicat
ion
O
p
tion
B
oard
63
ANLG
AUTO
SIGNAL
TYPE
(P.100)
Type of signal applied to analog auto reference input 0=0–10V; 1=+/–10V; 2=4- 20mA; 3=10- 50mA
*
This parameter is network-only. If the control source is changed from
NETWORK
to something else, this parameter is automatically reset to its default value.
Table 6.12 – FlexPak 3000 Alternate Register Map, Drop_3: Master Read Registers, FULL Connection. Runtime Signal Data (Drive Output Data)
Register
Bit
Parameter Name (Number)
Description
Settings
0
ANALOG
TACH
FEEDBACK
(P.291)
Analog tachometer feedback signal after all scaling
4095 at
TOP
SPEED
(P.011)
1
PULSE
TACH
FEEDBACK
(P.292)
Pulse encoder feedback signal after all scaling
4095 at
TOP
SPEED
(P.011)
2
SPD
LOOP
ERROR
(P.297)
Speed loop error
3
CML
REFERENCE
(P.396)
Amplitude and rate limited value of selected
CML
ref
4095 at
MAXIMUM
CURRENT
(P.007)
4
FIELD
REFERENCE
(P.590)
Field current reference
4095 at
MOTOR
HOT
FLD
AMPS
(P.510)
5
Reserved
Runtime signal data are updated by the regulator every 5msec, unless
FEEDBACK
SELECT
(P.200) is set to
ARMATURE
VOLT
, in which case the update time is 10 msec.
Table 6.13 – FlexPak 3000 Alternate Register Map, Drop_3: Master Read Registers, FULL Connection. Tunable, Configurable, and Status Data (Drive Output Data)
Register
Bit
Parameter Name (Number)
Description
Settings
6
CML
PI
PROP
GAIN
(P.301)
CML
PI
proportional gain
gain * 1000
7
CML
PI
LEAD
FREQUENCY
(P.302)
CML
PI
lead break frequency
radians/second
8
CML
REF
RATE
LIMIT
(P.303)
Min time for
CML
ref to go from zero to
MAXIMUM
CURRENT
milliseconds
9 to 11
Reserved
12
MAXIMUM
CURRENT
(P.007)
Highest amount of current, either positive or negative
% of
MOTOR
RATED
ARM
AMPS
(P.008)
13
MOTOR
RATED
ARM
AMPS
(P.008)
Rated armature current from motor nameplate
amps * 10
14
MOTOR
RATED
ARM
VOLTS
(P.009)
Rated armature voltage from motor nameplate
volts DC
15
FEEDBACK
SELECT
(P.200)
Type of feedback for speed/voltage loop feedback
0=
ARMATURE
VOLT
; 1=
DC
TACH
;
2=
PULSE TACH
; 3=
AC
TACH
16
ANALOG
TACH
GAIN
ADJ
(P.201)
Scales analog tachometer feedback signal
gain * 1000
17
ANALOG
TACH
ZERO
ADJ
(P.202)
Offset removed from analog tachometer feedback signal
Tunable, configurable, and status data are updated by the regulator approximately every 600 msec.
Table 6.11 – FlexPak 3000 Alternate Register Map, Drop_2: Master Write Registers, FULL Connection. Configurable Data (Drive Input Data) (Continued)
Register Bit Parameter Name (Number)
Description
Settings
Configurable data are read by the regulator approximately every 600 msec when Tune/Config Input Enable bit=1 and the drive is not running or jogging.