Table 5.15 – FlexPak 3000 Original Register Map, Drop_4: Master Read Registers, FULL Connection. Runtime Signal Data (Drive Output Data)
Register
Bit
Parameter Name (Number)
Description
Settings
0
I/O Expansion kit digital inputs
Bit-packed word that indicates the state of these inputs
*
*
The I/O Expansion kit digital inputs do not have fixed functions when
CONTROL
SOURCE
SELECT
(P.000) is set to
NETWORK
. Therefore, they do not select preset speeds,
change the
MOP
setpoint, or enable or disable the
OCL
.
0
I/O Expansion kit digital input 1 (Preset speed select 1)*
1
I/O Expansion kit digital input 2 (Preset speed select 2)*
2
I/O Expansion kit digital input 3 (mop decrement)*
3
I/O Expansion kit digital input 4 (mop increment)*
4
I/O Expansion kit digital input 5 (ocl enable)*
1
ANLG
IN
1 (P.492)
I/O Exp. kit analog input 1 after gain and zero applied
4095 at full scale
2
ANLG
IN
2 (P.493)
I/O Exp. kit analog input 2 after gain and zero applied
4095=full scale
3
FREQ
IN
(P.491)
I/O Expansion kit frequency input value after all scaling
4095=full scale
4 to 20
Reserved
Runtime signal data are updated by the regulator every 5 msec, unless
FEEDBACK
SELECT
(P.200) is set to
ARMATURE
VOLT
, in which case the update time is 10 msec.
Table 5.16 – FlexPak 3000 Original Register Map, Drop_4: Master Read Registers, FULL Connection. Tunable, Configurable, and Status Data (Drive Output Data)
Register
Bit
Parameter Name (Number)
Description
Settings
21
Level Detector Outputs
Bit-packed word indicating state of level detector outputs
0
Level detector 1 output
1
Level detector 2 output
Tunable, configurable and status data are updated by the regulator approximately every 600 msec.