Rockwell Automation FlexPak/WebPak 3000 DC Drive AutoMax Network Communication Board User Manual
Page 37

F
lex
Pak
3000 Drives
: O
rig
inal Regist
er
M
a
p
5-
7
Table 5.5 – FlexPak 3000 Original Register Map, Drop_1: Master Write Registers, BASIC and FULL Connections. Tunable Data (Drive Input Data)
Register
Bit
Parameter Name (Number)
Description
Settings
40
ACCELERATION
TIME
(P.001)
Min. time to accelerate from zero to
seconds * 10
41
DECELERATION
TIME
(P.002)
seconds * 10
42
MINIMUM
SPEED
(P.003)
Lowest operating speed
RPM
43
MAXIMUM
SPEED
(P.004)
Highest operating speed
RPM
44
POSITIVE
CURRENT
LIM
(P.005)
Highest amount of current for the forward bridge
% of
MOTOR
RATED
ARM
AMPS
(P.008)
45
NEGATIVE
CURRENT
LIM
(P.006)
Highest amount of current for reverse bridge
% of
MOTOR
RATED
ARM
AMPS
(P.008)
46
S
-
CURVE
ROUNDING
(P.014)
Amount of smoothing of speed/voltage loop reference
%
47
TRIM
RANGE
(P.109)
Amount the trim reference will affect the drive reference
%
48
SPD
LOOP
PI
PROP
GAIN
(P.211)
Speed loop
PI
proportional gain
gain * 100
49
SPD
LOOP
PI
LEAD
FREQ
(P.212)
Speed loop
PI
block lead break frequency
radians/second * 100
50
CML
PI
PROP
GAIN
(P.301)
CML
PI
proportional gain
gain * 1000
51
CML
PI
LEAD
FREQUENCY
(P.302)
CML
PI
lead break frequency
radians/second
52
CML
REF
RATE
LIMIT
(P.303)
milliseconds
53
JOG
SPEED
1 (P.012)
Operating speed while jogging
RPM
54
STOP
MODE
SELECT
(P.114)
Selects how drive responds to a normal stop command
0=
RAMP
; 1=
COAST
/
DB
; 2=
CURRENT
LIMIT
55
IR
COMPENSATION
(P.206)
Armature voltage loss compensation
%
56
CURRENT
COMPOUNDING
(P.209)
Sets the level of current compounding
%
57
NETW
COMM
LOSS
SELECT
(P.901)
How the drive responds to network communication loss
0=
FAULT
; 1=
USE
LAST
REF
; 2=
USE
TRMBLK
REF
,
3=
USE
TRMBLK
CNTL
58
NETW
OUT
REG
1
SELECT
(P.902) Number of the parameter readable in Drop_1, register 7
If no valid parameter value selected, this is set to
0=motor speed in
RPM
59
NETW
OUT
REG
2
SELECT
(P.903) Number of the parameter readable in Drop_1, register 8
If no valid parameter value selected, this is set to
0=armature voltage in volts
60
NETW
OUT
REG
3
SELECT
(P.904) Number of the parameter readable in Drop_1, register 9
If no valid parameter value selected, this is set to
0=armature current in amps*10 or amps
Tunable data are read by the regulator approximately every 600 msec while Tune/Config Input Enable bit=1