5-
8
Aut
o
Max
Net
w
or
k Comm
unicat
ion
O
p
tion
B
oard
Table 5.6 – FlexPak 3000 Original Register Map, Drop_1: Master Write Registers, BASIC and FULL Connections. Configurable Data (Drive Input Data)
Register Parameter Name (Number)
Description
Settings
61
FEEDBACK
SELECT
(P.200)
Type of feedback for speed/voltage loop feedback
0=
ARMATURE
VOLT
; 1=
DC
TACH
; 2 =
PULSE
TACH
; 3=
AC
TACH
62
NETW
CONNECT
TYPE
(P.910)
AutoMax network connection type
0=
BASIC
; 1=
FULL
63
AMX
NETW
REF
SELECT
(P.911)
AutoMax network reference selection
0=
DIRECT
; n=
BROADCAST
n (n=1 to 8)
Configurable data are read by the regulator approximately every 600 msec when Tune/Config Input Enable bit=1 and the drive is not running or jogging
Table 5.7 – FlexPak 3000 Original Register Map, Drop_2: Master Read Registers, FULL Connection. Runtime Signal Data (Drive Output Data)
Register
Parameter Name (Number)
Description
Settings
0
ANALOG
AUTO
REFERENCE
(P.188)
The analog reference value in auto mode after all scaling 4095 at
TOP
SPEED
(P.011)
1
Reserved
2
ANALOG
MAN
TRIM
REF
(P.194)
Analog manual trim reference input value
4095 at
TOP
SPEED
(P.011)
3 to 10
Reserved
Runtime signal data are updated by the regulator every 5 msec, unless
FEEDBACK
SELECT
(P.200) is set to
ARMATURE
VOLT
, in which case the update time is 10 msec.
Table 5.8 – FlexPak 3000 Original Register Map, Drop_2: Master Read Registers, FULL Connection. Tunable, Configurable, and Status Data (Drive Output Data)
Register
Bit
Parameter Name (Number)
Description
Settings
11
OCL
RAMP
OUTPUT
(P.846)
OCL
reference S-curve block output
4095
12
OCL
OUTPUT
(P.848)
Outer control loop output value
RPM
13
TOP
SPEED
(P.011)
Highest running speed of motor
RPM
14
JOG
SPEED
1 (P.012)
Operating speed while jogging
RPM
15
JOG
ACCEL
/
DECEL
TIME
(P.013)
Minimum time in which jog reference can change from
zero to
TOP
SPEED
(P.011) and from
TOP
SPEED
to zero
seconds * 10
16
S
-
CURVE
ROUNDING
(P.014)
Amount of smoothing of speed/voltage loop reference
%
17
REVERSE
DISABLE
(P.015)
Prevents speed/voltage loop ref. from going negative
0=
OFF
(bipolar ref); 1=
ON
(positive ref)
18
ANLG
AUTO
SIGNAL
TYPE
(P.100)
Type of signal applied to analog auto reference input
0=0-10V; 1=±10V; 2=4-20mA; 3=10-50mA
19
ANLG
AUTO
GAIN
ADJ
(P.101)
Scales analog auto reference signal
gain * 1000
20
ANLG
AUTO
ZERO
ADJ
(P.102)
Offset removed from analog auto reference signal
21
AUTO
REFERENCE
SELECT
(P.103)
Selects the type of auto reference
0=
ANALOG
; 1=
FREQUENCY
IN
22
ANLG
MAN
REF
GAIN
ADJ
(P.104)
Scales the analog manual reference gain
gain * 1000
Tunable, configurable, and status data are updated by the regulator approximately every 600 msec.