Rockwell Automation FlexPak/WebPak 3000 DC Drive AutoMax Network Communication Board User Manual
Page 59

F
lex
Pak
3000 Drives
: Alt
e
rnat
e Regist
er
M
a
p
6-
11
Table 6.8 – FlexPak 3000 Alternate Register Map, Drop_2: Master Read Registers, FULL Connection. Runtime Signal Data (Drive Output Data)
Register
Parameter Name (Number)
Description
Settings
0
SPD
SOURCE
SELECT
OUT
(P.193)
Selected speed/voltage loop reference value
4095 at
TOP
SPEED
(P.011)
Runtime signal data are updated by the regulator every 5 msec, unless
FEEDBACK
SELECT
(P.200) is set to
ARMATURE
VOLT
, in which case the update time is 10 msec.
Table 6.9 – FlexPak 3000 Alternate Register Map, Drop_2: Master Read Registers, FULL Connection. Tunable, Configurable, and Status Data (Drive Output Data)
Register
Bit
Parameter Name (Number)
Description
Settings
1
ACCELERATION
TIME
(P.001)
Min. time to accelerate from zero to
TOP
SPEED
(P.011)
seconds * 10
2
DECELERATION
TIME
(P.002)
Min. time to decelerate from
TOP
SPEED
(P.011) to zero
seconds * 10
3
MINIMUM
SPEED
(P.003)
Lowest operating speed
RPM
4
MAXIMUM
SPEED
(P.004)
Highest operating speed
RPM
5
POSITIVE
CURRENT
LIM
(P.005)
Highest amount of current for the forward bridge
% of
MOTOR
RATED
ARM
AMPS
(P.008)
6
NEGATIVE
CURRENT
LIM
(P.006)
Highest amount of current for reverse bridge
% of
MOTOR
RATED
ARM
AMPS
(P.008)
7
TRIM
RANGE
(P.109)
Amount the trim reference will affect the drive reference
%
8
SPD
LOOP
PI
PROP
GAIN
(P.211)
Speed loop
PI
proportional gain
gain * 100
9
SPD
LOOP
PI
LEAD
FREQ
(P.212)
Speed loop
PI
block lead break frequency
radians/second * 100
10
Reserved
11
OCL
RAMP
OUTPUT
(P.846)
OCL
reference S-curve block output
4095
12
Reserved
13
TOP
SPEED
(P.011)
Highest running speed of motor
RPM
14
JOG
SPEED
1 (P.012)
Operating speed while jogging
RPM
15
JOG
ACCEL
/
DECEL
TIME
(P.013)
Minimum time in which jog reference can go from zero to
TOP
SPEED
(P.011) and from
TOP
SPEED
to zero
seconds * 10
16
S
-
CURVE
ROUNDING
(P.014)
Smoothing of the speed/voltage loop reference
%
17
REVERSE
DISABLE
(P.015)
Prevents speed/voltage loop ref. from going negative
0=
OFF
(bipolar ref); 1=
ON
(positive ref)
18
ANLG
AUTO
SIGNAL
TYPE
(P.100)
Type of signal applied to analog auto reference input
0=0–10V; 1=±10V; 2=4-20mA; 3=10-50mA
19
ANLG
AUTO
GAIN
ADJ
(P.101)
Scales analog auto reference signal
gain * 1000
20
ANLG
AUTO
ZERO
ADJ
(P.102)
Offset removed from analog auto reference zero
21
AUTO
REFERENCE
SELECT
(P.103)
Selects the type of auto reference
0=
ANALOG
; 1=
FREQUENCY
IN
22
ANLG
MAN
REF
GAIN
ADJ
(P.104)
Scales the analog manual reference gain
gain * 1000
Tunable, configurable, and status data are updated by the regulator approximately every 600 msec.