WebPak 3000 Drives: Register Map
7-3
7.2
Diagnosing Processing Errors
In the alternate map, Drop_1, register 27, the number of the parameter that caused a
processing error (indicated by alternate map, register 0, bit 10) is now recorded. If
there are no processing errors, the value will be set to -1.
Because some parameters are processed in groups, it is not possible to always report
the specific parameter that is out of range. Instead, the first parameter number of the
group that contains the error is reported (see table 7.1).
For example, if
MOP
ACCEL
TIME
(P.115) was set out of range by the Network Option board, Drop_1, register
27 would contain the value 14 (
S
-
CURVE
ROUNDING
).
Parameters not listed in table
7.1 are handled on an individual basis by the parameter processing routines so the
parameter causing the processing error is reported by number directly. Also listed in
the table are possible non-user parameter numbers (
≥ 25000) that can cause
parameter processing errors.
Be aware that certain parameters are used as limits for other parameters (for example,
TOP
SPEED
(P.011) determines the maximum limit for
MAXIMUM
SPEED
(P.004).
The
WebPak 3000 Software Reference (D2-3444) describes the relationships between all
user parameters. It is also possible (but very unlikely) to get a processing error
reported for a non-user parameter number not listed below. If this occurs, the
Regulator board is suspect. Cycle power, and if another non-user parameter number
processing error occurs, replace the Regulator board.
Table 7.1 – Error Processing Parameters Reported by Group
Number
Reported
Parameter
Number
Parameter Name
Number
Reported
Parameter
Number
Parameter Name
004
004
003
012
113
MAXIMUM
SPEED
MINIMUM
SPEED
JOG
SPEED
1
STOP
SPEED
THRESHOLD
519
519
520
FLD
WEAKEN
PROP
GAIN
FLD
WEAKEN
LEAD
FREQ
005
005
006
POSITIVE
CURRENT
LIM
NEGATIVE
CURRENT
LIM
803
803
802
OCL
REF
ROUNDING
OCL
REF
RAMP
TIME
213
213
214
SPD
LEADLAG
RATIO
SPD
LEADLAG
LOW
FREQ
807
807
806
OCL
LEADLAG
RATIO
OCL
LEADLAG
LOW
REQ
014
014
001
002
018
013
S
-
CURVE
ROUNDING
ACCELERATION
TIME
DECELERATION
TIME
RAMP
STOP
DECEL
TIME
JOG
ACCEL
/
DECEL
TIME
900
900
910
NETW
DROP
NUMBER
NETW
CONNECT
TYPE
424
424
423
FREQ
IN
FULL
SCALE
FREQ
IN
ZERO
902
902
903
904
NETW
OUT
REG
1
SELECT
NETW
OUT
REG
2
SELECT
NETW
OUT
REG
3
SELECT
427
427
426
FREQ
OUT
FULL
SCALE
FREQ
OUT
ZERO
25200
25200
Trending Aquisition Rate
(set by WebPakCS)
510
510
516
MOTOR
HOT
FLD
AMPS
FLD
FEEDBACK
GAIN
ADJ
26015
SPD
LOOP
PI
INIT
SEL
(alternate, Drop_2,
reg 32)
514
514
515
FIELD
PI
PROP
GAIN
FIELD
PI
LEAD
FREQ