Rockwell Automation FlexPak/WebPak 3000 DC Drive AutoMax Network Communication Board User Manual
Page 65

F
lex
Pak
3000 Drives
: Alt
e
rnat
e Regist
er
M
a
p
6-
17
54
AUTO
REFERENCE
SELECT
(P.103)
Selects the type of auto reference
0=
ANALOG
; 1=
FREQUENCY
IN
55
MOTOR
HOT
FLD
AMPS
(P.510)
Rated hot field amps from motor nameplate
amps * 100
56
FIELD
LOSS
THRESHOLD
(P.512)
Field current level at which a field loss fault is generated
% of
MOTOR
HOT
FLD
AMPS
(P.510)
57
FIELD
AUTO
WEAKEN
(P.517)
Enables or disables automatic field weakening
0=
DISABLED
; 1=
ENABLED
58
MAXIMUM
CURRENT
(P.007)
Highest amount of current, either positive or negative
% of
MOTOR
RATED
ARM
AMPS
(P.008)
59
MOTOR
RATED
ARM
AMPS
(P.008)
Rated armature current from motor nameplate
amps * 10
60
MOTOR
RATED
ARM
VOLTS
(P.009)
Rated armature voltage from motor nameplate
volts DC
61
ANLG
TACH
VOLTS
/1000 (P.203)
Analog tach scaling from tach nameplate in V/1000
RPM
volts * 10
62
PULSE
TACH
PPR
(P.207)
Pulses per revolution from pulse encoder nameplate
63
PULSE
TACH
QUADRATURE
(P.208)
Enables or disables pulse encoder quadrature
0=
OFF
; 1=
ON
(quad decode)
Table 6.16 – FlexPak 3000 Alternate Register Map, Drop_4: Master Read Registers, FULL Connection. Tunable, Configurable, and Status Data (Drive Output Data)
Register
Bit
Parameter Name (Number)
Description
Settings
23
NOMINAL
AC
LINE
FREQ
(P.306)
Nominal AC line frequency
Hz
24
Reserved
25
PLL
MAXIMUM
ERROR
(P.308)
Max. allowed change in line period per AC line cycle
µsec
26
Reserved
27
ENHANCED
FLD
VOLT
ADJ
(P.500)
Adjusts the field output voltage
28
FIELD
ECONOMY
DELAY
(P.501)
Time between stopping and entering field economy
minutes
29
FIELD
ECONOMY
ACTIVE
(P.599)
Indicates the present state of field economy
0=
OFF
; 1=
ON
(field economy active)
30
OPEN
SCR
SENSITIVITY
(P.600)
Open
SCR
detection sensitivity adjustment
31
OPEN
SCR
TRIP
THRESH
(P.601)
Open
SCR
detection trip threshold
Tunable, configurable, and status data are updated by the regulator approximately every 600 msec.
Table 6.15 – FlexPak 3000 Alternate Register Map, Drop_3: Master Write Registers, FULL Connection. Configurable Data (Drive Input Data) (Continued)
Register
Bit
Parameter Name (Number)
Description
Settings
Configurable data are read by the regulator approximately every 600 msec when Tune/Config Input Enable bit=1 and the drive is not running or jogging.