Rockwell Automation FlexPak/WebPak 3000 DC Drive AutoMax Network Communication Board User Manual
Page 67

F
lex
Pak
3000 Drives
: Alt
e
rnat
e Regist
er
M
a
p
6-
19
49
DIG
OUT
2
SELECT
(P.411)
I/O Expansion kit digital output #2 source
0=
LEVEL
DETECT
1
OUTPUT
(P.648); 1=
LEVEL
DETECT
2
OUTPUT
(P.649); 2=in current limit; 3=drive ready; 4=
NETW
COMM
STATUS
(P.908); 5=bit 1 of Network Input Register 1;
6=bit 1 of Network Input Register 2; 7=bit 1 of Network
Input Register 3
50
0
DIG
OUT
1
CONTACT
TYP
(P.410)
I/O Expansion kit digital output 1 contact type
0=
NORMAL
OPEN
1=
NORMAL
CLOSED
1
DIG
OUT
2
CONTACT
TYP
(P.412)
I/O Expansion kit digital output 2 contact type
51
ANLG
IN
1
SIG
TYPE
(P.413)
I/O Expansion kit analog input 1 signal type
0=0-10 V; 1=±10 V; 2=4-20mA; 3=10-50mA
52
ANLG
OUT
1
SELECT
(P.418)
I/O Expansion kit analog output 1 source select
See “Settings for Analog and Frequency Outputs” on
page 4-8
53
ANLG
OUT
1
SIG
TYPE
(P.419)
I/O Expansion kit analog output 1 signal type
0=0–10 V; 1=+/–10 V; 2=4-20 mA
54
ANLG
OUT
2
SELECT
(P.421)
I/O Expansion kit analog output source select.
See “Settings for Analog and Frequency Outputs” on
page 4-8
55
FREQ
IN
ZERO
(P.423)
I/O Expansion kit minimum input frequency
kHz * 10
56
FREQ
IN
FULL
SCALE
(P.424)
I/O Expansion kit maximum input frequency
kHz * 10
57
FREQ
OUT
SELECT
(P.425)
I/O Expansion kit frequency output source select
See “Settings for Analog and Frequency Outputs” on
page 4-8.
58
FREQ
OUT
ZERO
(P.426)
I/O Exp. kit frequency generated when frequency output
signal is zero
kHz * 10
59
FREQ
OUT
FULL
SCALE
(P.427)
I/O Expansion kit frequency output at full scale
kHz * 10
60
LEVEL
DETECT
1
SELECT
(P.602)
Level detector 1 signal
0=
CML
FEEDBACK
; 1=
SPD
LOOP
FEEDBACK
; 2=
SPEED
RAMP
OUTPUT
; 3=
SPD
RAMP
INPUT
TP
; 4=
SPD
SOURCE
SELECT
OUT
61
LEVEL
DETECT
2
SELECT
(P.605)
Level detector 2 signal
62
NOMINAL
AC
LINE
FREQ
(P.306)
Nominal AC line frequency
Hz
63
NOMINAL
AC
LINE
VOLTS
(P.307)
Nominal AC line
RMS
voltage
volts
RMS
Table 6.18 – FlexPak 3000 Alternate Register Map, Drop_4: Master Write Registers, FULL Connection. Configurable Data (Drive Input Data) (Continued)
Register Bit Parameter Name (Number)
Description
Settings
Configurable data are read by the regulator approximately every 600 msec when Tune/Config Input Enable bit=1 and the drive is not running or jogging.