6 to 15 – Rockwell Automation FlexPak/WebPak 3000 DC Drive AutoMax Network Communication Board User Manual
Page 64

6-
16
Aut
o
Max
Net
w
or
k Comm
unicat
ion
O
p
tion
B
oard
40
ANALOG
TACH
GAIN
ADJ
(P.201)
Scales analog tachometer feedback signal
gain * 1000
41
ANALOG
TACH
ZERO
ADJ
(P.202)
Offset removed from analog tachometer feedback signal
42
ARM
VOLTAGE
GAIN
ADJ
(P.204)
Scales the armature voltage signal
gain * 1000
43
ARM
VOLTAGE
ZERO
ADJ
(P.205)
Offset removed from armature voltage feedback
44
SPD
LEADLAG
RATIO
(P.213)
Ratio between low and high break frequencies of speed
feedback lead/lag block
45
SPD
LEADLAG
LOW
FREQ
(P.214)
Low break frequency of speed feedback lead/lag block
radians/second * 100
46
SPD
LOOP
LAG
FREQ
(P.215)
Lag break frequency for the speed loop forward path lag
block
radians/second * 100
47
SPD
LEADLAG
SELECT
(P.216)
Speed/voltage loop lead/lag block select
0=
LEAD
/
LAG
; 1=
BYPASS
; 2=
LAG
/
LEAD
48
SPD
LOOP
LAG
BYPASS
(P.217)
Speed/voltage loop lag block bypass
0=
OFF
(not bypassed); 1=
ON
(bypassed)
49
CML
FEEDBACK
GAIN
ADJ
(P.300)
Current minor loop feedback gain adjust
gain * 1000
52
NETW
COMM
LOSS
SELECT
(P.901)
Selects how the drive responds to network
communication loss
0=
FAULT
; 1=
USE
LAST
REF
; 2=
USE
TRMBLK
REF
Table 6.15 – FlexPak 3000 Alternate Register Map, Drop_3: Master Write Registers, FULL Connection. Configurable Data (Drive Input Data)
Register
Bit
Parameter Name (Number)
Description
Settings
50
TACH
LOSS
SCR
ANGLE
(P.608)
SCR firing angle used in tach loss detection logic
degrees
51
FIELD
REF
SELECT
(P.521)
Selects reference source for the field current regulator
0 =
REGISTER
; 1=
ANALOG
MAN
TRIM
REF
;
2=
ANALOG
IN
1; 3=
ANALOG
IN
2
53
0
NEG
CUR
LIM
INV
EN
(P.226)
Enables negative current limit inverter
0 =
DISABLED
; 1 =
ENABLED
1
OCL
PROP
TRIM
SELECT
(P.813)
Sets
OCL
output proportional to absolute value of speed
reference at the output of the speed loop S-curve block
0 =
DISABLED
; 1 =
ENABLED
2
OCL
TYPE
3
POSN
REG
EN
(P.814
Implements type 3 position regulator
3
STOP
DECEL
SELECT
(P.122)
Selects the deceleration time for ramp stop sequences
1=
DECELERATION
TIME
; 2=
RAMP
STOP
DECEL
TIME
4
Reserved
5
CML
REF
LIMIT
SELECT
(P.311)
Source for
CML
positive and negative current limits
1=
SPD
LOOP
PI
LIMITS
; 2=
REGISTER
6 to 15 Reserved
Configurable data are read by the regulator approximately every 600 msec when Tune/Config Input Enable bit=1 and the drive is not running or jogging.
Table 6.14 – FlexPak 3000 Alternate Register Map, Drop_3: Master Write Registers, FULL Connection. Tunable Data (Drive Input Data) (Continued)
Register
Bit
Parameter Name (Number)
Description
Settings
Tunable data are read by the regulator approximately every 600 msec when Tune/Config Input Enable bit = 1.