Availability interpretation options, E 117) – Rockwell Automation FactoryTalk Metrics User Guide User Manual
Page 117

Collecting Performance Data Chapter 3
• Any scheduled Shift Change
• Summarization Criteria Change
• Scheduled Shift Start or Summarization Criteria Change
• Scheduled Shift Start and End or Summarization Criteria
Change
• Any scheduled Shift Change or Summarization Criteria
Change
• Performance Trending Summarization
Under Availability Interpretation Options, specify how
FactoryTalk Metrics should determine the overall availability.
Availability is determined by evaluating the Scheduled Availability
(page 65) and the Monitored Availability (page 73).
Select either of the following options:
• If both Scheduled Availability and Monitored Availability
indicate an Available state, the activity area is Available.
When you select this option, the Metrics Server Manager
calculates availability in the most restrictive way. It means that
the Scheduled Availability and the Monitored Availability
must both evaluate to available for the activity area to be
considered overall available.
This is the default setting.
• If either Scheduled Availability or Monitored Availability
indicate an Available state, the activity area is Available.
Availability Interpretation
Options
Rockwell Automation Publication PLTMT-UM001M-EN-P-June 2014
117