beautypg.com

Rockwell Automation 1771-QDC, D17716.5.93(Passport) PLASTIC MOLDING MODULE User Manual

Page 86

background image

Select Command and Status Bits to

Sequence Machine Operation

Chapter 6

6-10

Table 6.G

(continued)

Command and Configuration Bits

Operation:

Function Enabled

(when = 1):

QDC Block

Address:

ProĆSet

Address:

Logical Bridge

set output @ end of 1st clamp close profile

(0 = start 2nd clamp close profile)

CPC03ĆB08 B37/296

set output @ end of 2nd clamp close profile

(0 = start 3rd clamp close profile)

CPC03ĆB09 B37/297

set output @ end of 3rd clamp close profile

(0 = start clamp LP close profile)

CPC03ĆB10 B37/298

set output @ end of hold profile

(0 = start preĆdecompress movement @ end of hold)

HPC03ĆB08 B38/296

set output @ end of preĆdecompress movement

(0 = start plastication profile @ end of preĆdecompress)

HPC03ĆB09 B38/297

set output at end of plastication profile

(0 = start postĆdecompression at end of plastication)

PPC03ĆB08 B38/488

set output @ end of 1st clamp open profile

(0 = start 2nd clamp open profile)

OPC03ĆB08 B37/616

set output @ end of 2nd clamp open profile

(0 = start 3rd clamp open profile)

OPC03ĆB09 B37/617

set output @ end of 3rd clamp open profile

(0 = start clamp open slow profile)

OPC03ĆB10 B37/618

set output @ end of all ejector strokes

(0 = start each new stroke at end of previous)

EPC03ĆB12 B39/172

Configured

Protection from

ClampĆzone

Overrun

If a clamp close profile overruns the

mold protection zone:

0 = start LPĆclose profile

1 = stop and zero outputs

CPC03ĆB11 B37/299

If a clamp open profile overruns the

clamp open slow zone

0 = start open slow profile

1 = stop and zero outputs

OPC03ĆB11 B37/619

Additional Ejector

Configuration

start ejector profile on command from PLC processor

(0 = start ejector profile on position during clamp open)

EPC03ĆB08 B39/168

disable ejector profile

(0 = enable ejector profile)

EPC03ĆB09 B39/169

change intermediate strokes to tip strokes

(0 = all ejector strokes are full strokes)

EPC03ĆB13 B39/173

execute forward dwell after 1st advance stroke

(0 = execute forward dwell after last advance stroke)

EPC03ĆB15 B39/175