Jog Your Machine
Chapter 5
5-5
Take time now to develop ladder logic (independent of Pro-Set 600
software) to jog the ram (screw), clamp, and ejector. You may need to
monitor switches on your operator control panel, and set corresponding
command bits.
Use word 1 in the dynamic command block (DYC01) to enable and disable
individual jogs. Use word 1 in the system status block (SYS01) to monitor
the QDC module’s reaction to jog commands. Tables 5.A and 5.B identify
command and status bits for jogging the ram (screw), clamp, and ejector.
Table 5.A
Enable Bits for Ram (Screw), Clamp, and Ejector Jogs
Control Block Word: ProĆSet 600 Address: Description:
DYC01ĆB10
B34/394
Execute Ram (Screw) Jog Forward
DYC01ĆB11
B34/395
Execute Ram (Screw) Jog Reverse
DYC01ĆB12
B34/396
Execute Clamp Jog Forward
DYC01ĆB13
B34/397
Execute Clamp Jog Reverse
DYC01ĆB14
B34/398
Execute Ejector Jog Advance
DYC01ĆB15
B34/399
Execute Ejector Jog Retract
Table 5.B
Status Bits for Ram (Screw), Clamp, and Ejector Jogs
Status Block Word: ProĆSet 600 Address: Description:
SYS01ĆB10
B34/10
Ram (Screw) Jog Forward in Progress
SYS01ĆB11
B34/11
Ram (Screw) Jog Reverse in Progress
SYS01ĆB12
B34/12
Clamp Jog Forward in Progress
SYS01ĆB13
B34/13
Clamp Jog Reverse in Progress
SYS01ĆB14
B34/14
Ejector Jog Advance in Progress
SYS01ĆB15
B34/15
Ejector Jog Retract in Progress
We provide a programming example (Figure 5.1) of jog control for
instructional purposes only. Your application-specific programming may
vary significantly from this example.
Important: You may also need to develop ladder logic that changes the
direction of ram (screw), clamp, and/or ejector travel hydraulically when
you command the QDC module to jog in reverse.