Enter and download your worksheet values, 8ć38 – Rockwell Automation 1771-QDC, D17716.5.93(Passport) PLASTIC MOLDING MODULE User Manual
Page 155

Load Initial Profile Setpoints
Chapter 8
8-38
FOC Seg 3
(OPC17)
(OPC61)
FOC Seg 2
(OPC14)
Mold Safe
(CPC62)
FOC Seg 1
(OPC11)
Clamp Travel Range
Fully Open
(OPC62)
zero
4. Record your FOC end-of-segment position setpoints for OPC11, 14,
and 17 on Worksheet 8-E.
We recorded zero for the remaining position setpoints on Worksheet 8-E.
The valve spanning procedures in chapter 9 require these initial values.
We help you select correct final values for your application in chapter 10.
for additional information, refer to Section 3 of the Plastic Molding
Module Reference Manual (publication 1771-6.5.88).
Mold Open Dwell Timer Preset
(OPC63)
The QDC module starts its internal mold open dwell timer according to
how you set OPC03-B15.
We recorded zero for the mold open dwell timer preset.
The valve spanning procedures in chapter 9 require this initial value. We
help you select correct final values for your application in chapter 10. For
additional information, refer to Section 3 of the Plastic Molding Module
Reference Manual (publication 1771-6.5.88).
After you determine initial values and record them on Worksheet 8-E, you
are ready to proceed. Refer to procedures in chapter 4 if necessary.
Important: Be sure that you do not alter any setpoints, and that you enter
each and every setpoint exactly as on the worksheet.
1. Enter all worksheet values into your PLC-5 data table.
2. Download command blocks to the QDC module. We repeat the OPC
block download data.
Block to
Download:
ProĆSet 600
Block ID:
Download
Command Bit:
Companion
Block:
OPC
21
B21/20
none
3. Check SYS61 and SYS62 for programming errors. Correct as needed.
Enter and Download Your