Download mcc parameters to the qdc module, Configure the qdc module's i/o chapter 3, Enter mcc parameters into your plcć5 data table – Rockwell Automation 1771-QDC, D17716.5.93(Passport) PLASTIC MOLDING MODULE User Manual
Page 49

Record Your Initial Values Here
Configure the QDC Module's I/O
Chapter 3
3-5
Worksheet 3ĆD
Determine Initial SensorĆconfiguration Values
Input
Line
Control Word
ProĆSet 600 Addr. Value
Description
1
1
MCC09
N40:5
0
Minimum Screw Position
1
2
MCC10
N40:6
Maximum Screw Position
1
3
MCC11
N40:7
Analog Signal @ Min Screw Position
2
4
MCC12
N40:8
Analog Signal @ Max Screw Position
2
2
5
MCC57
N40:53
0
Minimum System Pressure
3
6
MCC58
N40:54
Maximum System Pressure
3
7
MCC59
N40:55
Analog Signal @ Min System Pressure
2
8
MCC60
N40:56
Analog Signal @ Max System Pressure
2
3
9
MCC23
N40:19
0
Minimum Clamp Position
1
10
MCC24
N40:20
Maximum Clamp Position
1
11
MCC25
N40:21
Analog Signal @ Min Clamp Position
2
12
MCC26
N40.22
Analog Signal @ Max Clamp Position
2
4
13
MCC31
N40:27
0
Minimum Ejector Position
1
14
MCC32
N40:28
Maximum Ejector Position
1
15
MCC33
N40:29
Analog Signal @ Min Ejector Position
2
16
MCC34
N40:30
Analog Signal @ Max Ejector Position
2
1
Incremental Distance
2
Input Signal Range
3
Pressure
00.00 to 99.99in 00.00 to 10.00VDC or
0000 to 9999 PSI
000.0 to 999.9mm 01.00 to 05.00VDC or 000.0 to 999.9 Bar
04.00 to 20.00MADC
Use this download procedure now and later in this chapter. The procedure
requires you to complete the following general steps:
enter MCC parameters into the PLC-5 data table
download them to the QDC module (with PLC-5 processor in run mode)
correct any programming errors
Next, we describe the general steps.
Enter MCC Parameters into Your PLCĆ5 Data Table
With your programming terminal, enter values from Worksheet 3-A thru
4-D into your PLC-5 data table as follows:
1. Switch the PLC-5 processor to
PROGRAM
mode.
2. Display your PLC-5 data table.
Download MCC Parameters
to the QDC Module