Select Command and Status Bits to
Sequence Machine Operation
Chapter 6
6-4
Table 6.D
Command Bits To Interrupt Movement Between Profiles
To Perform T his Function
Use This Bit
ProĆSet
Address:
Start 2nd clamp close profile @ endĆof 1st
Stop and setĆoutput @ endĆof 1st
CPC03ĆB08 = 0
= 1
B37/296
Start 3rd clamp close profile @ endĆof 2nd
Stop and setĆoutput @ endĆof 2nd
CPC03ĆB09 = 0
= 1
B37/297
Start LP close profile @ endĆof 3rd
Stop and setĆoutput @ endĆof 3rd
CPC03ĆB10 = 0
= 1
B37/298
Start 2nd clamp open profile @ endĆof 1st
Stop and setĆoutput @ endĆof 1st
OPC03ĆB08 = 0
= 1
B37/616
Start 3rd clamp open profile @ endĆof 2nd
Stop and setĆoutput @ endĆof 2nd
OPC03ĆB09 = 0
= 1
B37/617
Start clamp open slow profile @ endĆof 3rd
Stop and setĆoutput @ endĆof 3rd
OPC03ĆB10 = 0
= 1
B37/618
Start ejector profile on clamp position
Start ejector profile on command
EPC03ĆB08 = 0
= 1
B39/168
Enable ejector profile
Disable ejector profile
EPC03ĆB09 = 0
= 1
B39/169
Run ejector profile without interruption
Stop and notify @ end of ejector stroke
EPC03ĆB12 = 0
= 1
B39/172
Start preĆdecompression movement @ endĆof hold
Stop and set output @ endĆof hold
HPC03ĆB08 = 0
= 1
B38/296
Start plastication profile @ endĆof preĆdecompression
Stop and set output @ endĆof preĆdecompression
HPC03ĆB09 = 0
= 1
B38/297
Start postĆdecompression movement @ endĆof plastication
Stop and set output @ endĆof plastication
PPC03ĆB08 = 0
= 1
B38/488
Important: In any of these bit tables, disregard bits not needed by your