Use command and status bit tables – Rockwell Automation 1771-QDC, D17716.5.93(Passport) PLASTIC MOLDING MODULE User Manual
Page 78

Select Command and Status Bits to
Sequence Machine Operation
Chapter 6
6-2
Use the following tables to select command and status bits when writing
ladder logic to control manual functions and machine sequencing.
Table 6.A
Command and Status Bits for Manual Control
To Initiate this action:
Set this bit:
ProĆSet
B34/xx:
The QDC sets this bit
during execution:
ProĆSet
B34/xx:
Direct SetĆoutput
DYC01ĆB08
392
SYS01ĆB08
08
Unassigned #1 Jog
DYC01ĆB09
393
SYS01ĆB09
09
Ram (screw) Forward Jog DYC01ĆB10
394
SYS01ĆB10
10
Ram (screw) Reverse Jog DYC01ĆB11
395
SYS01ĆB11
11
Clamp Forward Jog
DYC01ĆB12
396
SYS01ĆB12
12
Clamp Reverse Jog
DYC01ĆB13
397
SYS01ĆB13
13
Ejector Advance Jog
DYC01ĆB14
398
SYS01ĆB14
14
Ejector Retract Jog
DYC01ĆB15
399
SYS01ĆB15
15
Stop
DYC02ĆB15
415
SYS02ĆB15
31
Table 6.B
Command Bits for Starting Profiles
To initiate this
Profile/Movement:
Toggle this
bit in DYC02:
ProĆSet
B34/xx:
If this bit is
Reset:
ProĆSet
Address:
The Profile/Movement in column 1
starts automatically after:
1st Clamp Close
00
400
---
---
---
2nd Clamp Close
01
401
CPC03ĆB08
B37/296
1st Clamp Close
3rd Clamp Close
02
402
CPC03ĆB09
B37/297
2nd Clamp Close
Low Pressure Close
03
403
CPC03ĆB10
B37/298
3rd Clamp Close
Injection
04
404
1
---
---
---
Pack
05
405
1
---
---
Injection
Hold
06
406
1
---
---
Pack
PreĆdecompression
07
407
HPC03ĆB08
B38/296
Hold
Plastication
08
408
HPC03ĆB09
B38/297
PreĆdecompression
PostĆdecompression
09
409
PPC03ĆB08
B38/488
Plastication
1st Clamp Open
10
410
---
---
---
2nd Clamp Open
11
411
OPC03ĆB08
B37/616
1st Clamp Open
3rd Clamp Open
12
412
OPC03ĆB09
B37/617
2nd Clamp Open
Clamp Open Slow
13
413
OPC03ĆB10
B37/618
3rd Clamp Open
1st Ejector Advance
14
414
EPC03ĆB08
B39/168
On Clamp Position During Open
Ejector Continue
15
415
EPC03ĆB12
B39/172
Previous Ejector Stroke
1
Injection, Pack, and Hold are always linked as one profile.
Use Command and Status