Configure the qdc module's i/o chapter 3 – Rockwell Automation 1771-QDC, D17716.5.93(Passport) PLASTIC MOLDING MODULE User Manual
Page 59

Record Your SWTL Configuration Values Here
Configure the QDC Module's I/O
Chapter 3
3-15
Configure the QDC module for SWTL alarms as follows:
1.
Determine these SWTL values for ram (screw), clamp, and/or ejector
travel with respect to the range of physical travel.
SWTL deadband
Maximum SWTL
Minimum SWTL
2.
Record non-zero SWTL values on Worksheet 3-F. Zero values
disable the corresponding SWTLs.
ATTENTION: Leaving your SWTL settings at zero (MCC13,
14, 27, 28, 41, 42) inhibits the QDC module from performing
this safety function.
Worksheet 3ĆF
SWTL Configuration Values
Control Word
ProĆSet 600 Addr. Value
Description
MCC13
N40:9
Screw Minimum SWTL
1
MCC14
N40:10
Screw Maximum SWTL
1
MCC15
N40:11
10
Screw SWTL Deadband
2
MCC27
N40:23
Clamp Minimum SWTL
1
MCC28
N40:24
Clamp Maximum SWTL
1
MCC29
N40:25
10
Clamp SWTL Deadband
2
MCC41
N40:37
Ejector Minimum SWTL
1
MCC42
N40:38
Ejector Maximum SWTL
1
MCC43
N40:39
10
Ejector SWTL Deadband
2
1
Incremental distance measured from zero
2
Incremental distance measured as noted
00.00 to 99.99 Inches
00.00 to 99.99 Inches
000.0 to 999.9 Millimeters
000.0 to 999.9 Millimeters
You may now download your adjusted values to the QDC module using
the MCC download procedure presented earlier in this chapter.