Blank worksheets appendix a – Rockwell Automation 1771-QDC, D17716.5.93(Passport) PLASTIC MOLDING MODULE User Manual
Page 283

Enter Your Values Here
Blank Worksheets
Appendix A
A-17
Worksheet 7ĆE (continued)
Hold Configuration Block (HDC)
Control Word ProĆSet 600 Addr. Value
Description
Units
HDC06
N44:182
1000
Minimum ERC PercentageĆĆPressure
Percent
8
HDC09
N44:185
*
Output #1 SetĆoutput Value During Profile
Percent Signal Output
4
HDC10
N44:186
*
Output #2 SetĆoutput Value During Profile
Percent Signal Output
4
HDC11
N44:187
*
Output #3 SetĆoutput Value During Profile
Percent Signal Output
4
HDC12
N44:188
*
Output #4 SetĆoutput Value During Profile
Percent Signal Output
4
HDC17
N44:193
0
Output #1 Acceleration Ramp Rate During Profile
Percent Signal Output per Second
5
HDC18
N44:194
0
Output #2 Acceleration Ramp Rate During Profile
Percent Signal Output per Second
5
HDC19
N44:195
0
Output #3 Acceleration Ramp Rate During Profile
Percent Signal Output per Second
5
HDC20
N44:196
0
Output #4 Acceleration Ramp Rate During Profile
Percent Signal Output per Second
5
HDC25
N44:201
0
Output #1 Deceleration Ramp Rate During Profile
Percent Signal Output per Second
5
HDC26
N44:202
0
Output #2 Deceleration Ramp Rate During Profile
Percent Signal Output per Second
5
HDC27
N44:203
0
Output #3 Deceleration Ramp Rate During Profile
Percent Signal Output per Second
5
HDC28
N44:204
0
Output #4 Deceleration Ramp Rate During Profile
Percent Signal Output per Second
5
HDC33
N44:209
*
Output #1 SetĆoutput Value at EndĆof Profile
Percent Signal Output
4
HDC34
N44:210
*
Output #2 SetĆoutput Value at EndĆof Profile
Percent Signal Output
4
HDC35
N44:211
*
Output #3 SetĆoutput Value at EndĆof Profile
Percent Signal Output
4
HDC36
N44:212
*
Output #4 SetĆoutput Value at EndĆof Profile
Percent Signal Output
4
HDC41
N44:217
0
Pressure Minimum Control Limit
Pressure
3
HDC42
N44:218
*
Pressure Maximum Control Limit
Pressure
3
HDC43
N44:219
*
Selected Pressure Valve, Output for Minimum
Percent Signal Output
4
HDC44
N44:220
*
Selected Pressure Valve, Output for Maximum
Percent Signal Output
4
HDC49
N44:225
100
Proportional Gain for Pressure Control
None
HDC50
N44:226
400
Integral Gain for Pressure Control
Inverse Time (algorithm)
6
HDC51
N44:227
0
Derivative Gain for Pressure Control
Time (algorithm)
7
HDC57
N44:233
0
Profile High Pressure Alarm Setpoint
Pressure
3
3
Pressure
4
Percent Signal Output
0000 to 9999 PSI 00.00 to 99.99
000.0 to 999.9 Bar
5
Percent Signal Output per Second
6
Inverse Time (Algorithm)
7
Time (Algorithm)
8
Percent
0000 to 9999 00.00 to 99.99 Minutes (ISA) 00.00 to 99.99 Minutes (ISA) 00.00 to 99.99
00.00 to 99.99 Seconds (AĆB) 00.00 to 99.99 Seconds (AĆB)
* Refer to the appropriate section later in this chapter for information on this parameter