Record Your Final Values Here
Configure the QDC Module's I/O
Chapter 3
3-9
Worksheet 3ĆE
Final SensorĆconfiguration Values
Input
Line
Control Word
ProĆSet 600 Addr. Value
Description
1
1
MCC09
N40:5
0
Minimum Screw Position
1
2
MCC10
N40:6
Maximum Screw Position
1
3
MCC11
N40:7
Analog Signal @ Min Screw Position
2
4
MCC12
N40:8
Analog Signal @ Max Screw Position
2
2
5
MCC57
N40:53
0
Minimum System Pressure
3
6
MCC58
N40:54
Maximum System Pressure
3
7
MCC59
N40:55
Analog Signal @ Min System Pressure
2
8
MCC60
N40:56
Analog Signal @ Max System Pressure
2
3
9
MCC23
N40:19
0
Minimum Clamp Position
1
10
MCC24
N40:20
Maximum Clamp Position
1
11
MCC25
N40:21
Analog Signal @ Min Clamp Position
2
12
MCC26
N40:22
Analog Signal @ Max Clamp Position
2
4
13
MCC31
N40:27
0
Minimum Ejector Position
1
14
MCC32
N40:28
Maximum Ejector Position
1
15
MCC33
N40:29
Analog Signal @ Min Ejector Position
2
16
MCC34
N40:30
Analog Signal @ Max Ejector Position
2
1
Incremental Distance
2
Input Signal Range
3
Pressure
00.00 to 99.99in
00.00 to 10.00VDC or
0000 to 9999 PSI
000.0 to 999.9mm
01.00 to 05.00VDC or
000.0 to 999.9 Bar
04.00 to 20.00MADC
Determine Values for Ram (Screw) Position Sensor
ATTENTION: Incorrect values entered in DYC09-12 may
result in rapid ram (screw) motion and potential damage to your
barrel and seals of your injection cylinder.
To complete the configuration for your ram (screw) position sensor, do the
following and enter the results on Worksheet 3-E:
1.
Move the ram (screw) forward until it reaches its mechanical stop at
the nozzle end. This is the zero position.
2.
Remove ram (screw) pressure and/or flow to stop movement.