Rockwell Automation 1771-QDC, D17716.5.93(Passport) PLASTIC MOLDING MODULE User Manual
Page 192
Span Your Valves
Chapter 9
9-26
Set New Values for the Velocity vs. Position Profile
If necessary, refer to chapter 8 for when you determine the following:
8ĆB
Velocity vs. position algorithm
IPC03ĆB01 = B00 = 0
B38/96, 97
Transition setpoints:
Time limit
Ram (screw) position
Ram (screw) pressure
Cavity pressure
Minimum position for pressure transition
IPC60 = above typical
IPC61 = estimated top of cushion
IPC62 = below mold flash pressure
IPC63 = zero to inhibit
IPC64 = zero to inhibit
N44:116
N44:117
N44:118
N44:119
N44:120
Download new values to the QDC module by downloading INC.
Important: If downloading from your programming terminal, download
INC followed by IPC (chapter 4).
To download:
Set: B21/
INC
7
IPC
8
Span Your Injection Velocity Valve
Span your injection valve for smooth operation at the highest desired
velocity. Do this by finding optimum values for these words:
Minimum Velocity Control Limit INC45 (N44:41)
Maximum Velocity Control Limit INC46 (N44:42)
Selected Velocity Valve, Output for Minimum INC47 (N44:43)
Selected Velocity Valve, output for maximum INC48 (N44:44)
Important: If PanelView is operational for injection profiles, use it to:
observe
actuals
change and download setpoints
run
profiles
Important:
We suggest that you read this procedure before starting.
ATTENTION: As with any machine start-up, install a test
mold. Programming errors, configuration errors, or hydraulic
problems could lead to personal injury and/or machine damage.
ATTENTION: Be sure all machine guards and shields are in
place before proceeding to guard against personal injury.