Rockwell Automation 1766-Lxxxx MicroLogix 1400 Programmable Controllers User Manual User Manual
Page 362
322
Rockwell Automation Publication 1766-UM001H-EN-P - May 2014
Appendix F MicroLogix 1400 Distributed Network Protocol (DNP3)
23
1
Frozen Counter Event - 32-bit
with flag
1 (read)
06 (no range, or all)
07, 08 (limited qty)
129 (response)
130 (unsol. resp)
17, 28 (index)
23
2
Frozen Counter Event - 16-bit
with flag
1 (read)
06 (no range, or all)
07, 08 (limited qty)
129 (response)
130 (unsol. resp)
17, 28 (index)
23
5
Frozen Counter Event - 32-bit
with flag and time
1 (read)
06 (no range, or all)
07, 08 (limited qty)
129 (response)
130 (unsol. resp)
17, 28 (index)
23
6
Frozen Counter Event - 16-bit
with flag and time
1 (read)
06 (no range, or all)
07, 08 (limited qty)
129 (response)
130 (unsol. resp)
17, 28 (index)
30
0
Analog Input - Any Variation
1 (read)
00, 01 (start-stop)
06 (no range, or all)
30
1
Analog Input - 32-bit with flag
1 (read)
00, 01 (start-stop)
06 (no range, or all)
129 (response)
00, 01 (start-stop)
30
2
Analog Input - 16-bit with flag
1 (read)
00, 01 (start-stop)
06 (no range, or all)
129 (response)
00, 01 (start-stop)
30
3
Analog Input - 32-bit without
flag
1 (read)
00, 01 (start-stop)
06 (no range, or all)
129 (response)
00, 01 (start-stop)
30
4
Analog Input - 16-bit without
flag
1 (read)
00, 01 (start-stop)
06 (no range, or all)
129 (response)
00, 01 (start-stop)
30
5
Analog Input - Single-prec flt-pt
with flag
1 (read)
00, 01 (start-stop)
06 (no range, or all)
129 (response)
00, 01 (start-stop)
32
0
Analog Input Event - Any
Variation
1 (read)
06 (no range, or all)
07, 08 (limited qty)
32
1
Analog Input Event - 32-bit
without time
1 (read)
06 (no range, or all)
07, 08 (limited qty)
129 (response)
130 (unsol. resp)
17, 28 (index)
32
2
Analog Input Event - 16-bit
without time
1 (read)
06 (no range, or all)
07, 08 (limited qty)
129 (response)
130 (unsol. resp)
17, 28 (index)
32
3
Analog Input Event - 32-bit with
time
1 (read)
06 (no range, or all)
07, 08 (limited qty)
129 (response)
130 (unsol. resp)
17, 28 (index)
32
4
Analog Input Event - 16-bit with
time
1 (read)
06 (no range, or all)
07, 08 (limited qty)
129 (response)
130 (unsol. resp)
17, 28 (index)
32
5
Analog Input Event - Single-prec
flt-pt without time
1 (read)
06 (no range, or all)
07, 08 (limited qty)
129 (response)
130 (unsol. resp)
17, 28 (index)
32
7
Analog Input Event - Single-prec
flt-pt with time
1 (read)
06 (no range, or all)
07, 08 (limited qty)
129 (response)
130 (unsol. resp)
17, 28 (index)
40
0
Analog Output Status - Any
Variation
1 (read)
00, 01 (start-stop)
06 (no range, or all)
40
1
Analog Output Status - 32-bit
with flag
1 (read)
00, 01 (start-stop)
06 (no range, or all)
129 (response)
00, 01 (start-stop)
40
2
Analog Output Status - 16-bit
with flag
1 (read)
00, 01 (start-stop)
06 (no range, or all)
129 (response)
00, 01 (start-stop)
40
3
Analog Output Status -
Single-prec flt-pt with flag
1 (read)
00, 01 (start-stop)
06 (no range, or all)
129 (response)
00, 01 (start-stop)
Implementation Table for Series B controllers
DNP Object Group & Variation
Request
DNP3 Master may issue
MicroLogix 1400 must parse
Response
DNP3 Master must parse
MicroLogix 1400 may issue
Group
Num
Var Num Description
Function Codes
(dec)
Qualifier Codes (hex)
Function Codes
(dec)
Qualifier Codes
(hex)