Using trim pots, Trim pot operation – Rockwell Automation 1766-Lxxxx MicroLogix 1400 Programmable Controllers User Manual User Manual
Page 147
Rockwell Automation Publication 1766-UM001H-EN-P - May 2014
105
Using the LCD Chapter 5
7. To change the HTTP setting, press the Up or Down key and press the OK
key to apply the change.
Using Trim Pots
Trim Pot Operation
The MicroLogix 1400 controller provides two trimming potentiometers (trim
pots, POT0 and POT1) which allow modification of integer data within the
controller. The data value of each trim pot can be used throughout the control
program for timers, counters, analog presets, depending upon the
requirements of the application.
You can change the data value of each trim pot using the trim pot screens
provided by the LCD. To access to the Trim Pot Set screen, which is the top
screen for the trim pot functionality, select trim pot Set on the LCD default
menu screen, as shown below, and press the OK key on the LCD keypad.
Trim pot data is updated continuously whenever the controller is powered-up.
TIP
To exit the Protocol Setup Menu, press the ESC key on the LCD
keypad at any time.