Human Interface Module
3–7
Program and Display Modes
Press these keys . . .
while following these steps . . .
The HIM Display will show . . .
1. The Display and Program modes allow access to the parameters for viewing or
programming.
A. From the Status Display, press Enter (or any key). “Choose Mode” will be
shown.
B. Press the Increment (or Decrement) key to show “Program” (or “Display”).
C. Press Enter.
D. Press the Increment (or Decrement) key until the desired group is displayed.
E. Press Enter.
F.
Press the Increment (or Decrement) key to scroll to the desired parameter.
Choose Mode
Display
Choose Mode
Program
Choose Group
Metering
Output Current
0.00 Amps
Bit ENUMs (16 character text strings) will be displayed (except Series A HIMs
below software version 3.0) to aid interpretation of bit parameters.
G. Select a bit parameter with the Increment (or Decrement) keys.
H. Press the SELect key to view the ENUM of the first bit. Pressing this key
again will move the cursor to the left one bit.
A blinking underline cursor will indicate that you are in the Display mode or
that a Read Only parameter as been accessed. A flashing character will
indicate that the value can be changed.
Individual bits of a Read/Write parameter can be changed in the same man-
ner. Pressing the SELect key will move the cursor (flashing character) one
bit to the left. That bit can then be changed by pressing the Increment/
Decrement keys. When the cursor is in the far right position, pressing the
Increment/Decrement keys will increment or decrement the entire value.
Masks
Logic Mask
TB3
X1111111
or
or
or
or
Process Mode
Press these keys . . .
while following these steps . . .
The HIM Display will show . . .
Process Mode
1. When selected, the Process mode will show a custom display consisting of
information programmed with the Process Display group of parameters.
A. Follow steps A-C on the preceding page to access the Program mode.
B. Press the Increment/Decrement key until “Process Display” is shown. Press
Enter.
C. Using the Increment/Decrement keys, select [Process 1 Par] and enter the
number of the parameter you wish to monitor. Press Enter.
Choose Mode
Program
Choose Group
Process Display
Process 1 Par
1
or
&
or
&