Programming
Owners
This group of parameters contains binary information to display which group of adapters
are issuing control commands.
Each Owner Parameter contains a bit for each adapter.
The drive will set an adapter’s bit to “1” when that adapter
is issuing a logic command and to “Zero” when no com-
mand is being issued.
A Status description (bit ENUM) is displayed on line 1 (ex-
cept Series A HIMs below version 3.0).
[Stop Owner]
This parameter displays which adapters are presently is-
suing a valid stop command.
Parameter Number
102
Parameter Type
Read Only
Units
Display Drive
“0” 0
Stop Input Not Present
“1” 1
Stop Input Present
[Direction Owner]
This parameter displays which adapter currently has ex-
clusive control of direction changes.
If [Freq Select 1] or [Freq Select 2] is set to “Analog In 0”
and an Analog Option Board with bipolar input (LA6, LA7)
is installed, that input (designated “Analog In 0”) will have
exclusive ownership of direction. Bit 7 of [Direction Mask]
must not be set to “0” and no other device can have claimed
ownership of direction (i.e. TB3 - Run Reverse). If either
condition is true, a fault will be issued.
Parameter Number
103
Parameter Type
Read Only
Units
Display Drive
“0” 0
Non-Owner
“1” 1
Current Owner
[Start Owner]
This parameter displays which adapters are presently is-
suing a valid start command.
Parameter Number
104
Parameter Type
Read Only
Units
Display Drive
“0” 0
Start Input Not Present
“1” 1
Start Input Present
[Jog Owner]
This parameter displays which adapters are presently is-
suing a valid jog command.
Parameter Number
105
Parameter Type
Read Only
Units
Display Drive
“0” 0
Jog Input Not Present
“1” 1
Jog Input Present
[Reference Owner]
This parameter displays which adapter currently has the
exclusive control of the selection of the command frequen-
cy source.
Parameter Number
106
Parameter Type
Read Only
Units
Display Drive
“0” 0
Non-Owner
“1” 1
Current Owner
[Accel Owner]
This parameter displays which adapter has exclusive con-
trol of selecting [Accel Time 1] or [Accel Time 2].
Parameter Number
107
Parameter Type
Read Only
Units
Display Drive
“0” 0
Non-Owner
“1” 1
Current Owner
TB3
Adapter 1
Adapter 2
Adapter 3
Adapter 4
Adapter 5
Adapter 6
Not Used
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Owners Display