If your drive was received with Analog Options (LA1, LA2, etc.)
factory installed, the boards must be setup before use. Proceed to
“Option Board Setup” below.
Option Board Installation/Removal
If the drive is not factory configured with Analog Options, the desired
option boards can be user installed. Prior to installation, the jumpers
at J9 and/or J10 must be removed. If a board is removed at a later
time, the jumpers must be reinstalled. Refer to the detailed instruc-
tions supplied with the option boards.
Important:
Drive power must be removed prior to jumper installation/
removal.
Option Board Setup
Before operation, each installed option board must configured. The
board will have one or two DIP switches depending on the option
selected. The first function (input or output) is configured with the S1
DIP switch – the second function (if present) is configured with S51.
Using the table below, set the switch(es) for correct operation.
Important:
Due to different switch manufacturers, the individual
switches will be designated “A or 1” and “B or 2.” In
addition, switch positions will be indicated as “Off or 0”
and “On or 1.”
S1 and S51 Configuration Settings
Option
DIP Switch S1
DIP Switch S51
Function Mode
Switch Setting
Function Mode
Switch Setting
A/1
B/2
A/1
B/2
LA1
Output 0 10V
Off/“0”
Off/“0”
Configure Standard Analog Input 2 with J11.
See page
for further information.
20mA On/“1”
On/“1”
LA2
Input 0
10V
Off/“0”
On/“1”
Input 1
10V
Off/“0”
On/“1”
20mA On/“1”
Off/“0”
20mA On/“1”
Off/“0”
LA3
Output 0 10V
Off/“0”
Off/“0”
Output 1 10V
Off/“0”
Off/“0”
20mA On/“1”
On/“1”
20mA On/“1”
On/“1”
LA4
Input 2
10V
Off/“0”
On/“1”
Output 1 10V
Off/“0”
Off/“0”
20mA On/“1”
Off/“0”
20mA On/“1”
On/“1”
LA5
Output 0 10V
Off/“0”
Off/“0”
20mA On/“1”
On/“1”
LA6
Input 0
10V
Off/“0”
On/“1”
20mA On/“1”
Off/“0”
LA7
Input 0
10V
Off/“0”
On/“1”
Input 1
10V
Off/“0”
On/“1”
20mA On/“1”
Off/“0”
20mA On/“1”
Off/“0”
1
2
On / 1 =
Off / 0 =
Switches S1 and S51