Chapter 7
Programming Parameters
7-73
Parameter 902 – Trend Constant Signed Value [Trend Sign Val]
Internal units : None
Programming Terminal units: None
Minimum Value: – 32767
Maximum Value: + 32767
Default Value: 0
Description: This parameter specifies a signed constant value used
for trend trigger evaluation. This parameter number is entered when
programming Trend Operand Parameter X or Y.
Parameter 903 – Trend Constant Signed Value [Trend Sign Val]
Internal units : None
Programming Terminal units: None
Minimum Value: – 32767
Maximum Value: + 32767
Default Value: 0
Description: This parameter specifies a signed constant value used
for trend trigger evaluation. This parameter number is entered when
programming Trend Operand Parameter X or Y.
Parameter 904 – Trend Constant Logic Value [Trend Logic Val]
Internal units : None
Programming Terminal units: None
Minimum Value: 0000 0000 0000 0000
Maximum Value: 1111 1111 1111 1111
Default Value: 0000 0000 0000 0000
Description: This parameter specifies a bit(s) value used for trend
trigger evaluation. This parameter number is entered when
programming Trend Operand Parameter X or Y. The default value is
zero.
Parameter 905 – Trend Constant Logic Value [Trend Logic Val]
Internal units : None
Programming Terminal units: None
Minimum Value: 0000 0000 0000 0000
Maximum Value: 1111 1111 1111 1111
Default Value: 0000 0000 0000 0000
Description: This parameter specifies a bit(s) value used for trend
trigger evaluation. This parameter number is entered when
programming Trend Operand Parameter X or Y. The default value is
zero.