PARM
716
717
718
719
720
721
722
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
780
840
841
842
843
844
900
901
902
903
UNITS
%
RPM
RPM
RPM
SEC
SEC
SEC
SEC
%
SEC
%
%
Rad/Sec
Rad/Sec
Volts
X.XX
NAME
Proc Trim KP
Proc Tri Lo Lim
Proc Trim Hi Lim
Proce Trim Out K
Ovld Pend Level
Proc Trim Lo Sum
Proc Trim Hi Sum
ABS Overspeed
Ext Overtemp Dly
SCR Overtemp Dly
Stall Delay
AC Line Tol Dly
Field Fault Threshold
Fld Failure Dly
Tach Loss CEMF
Tach Loss Vel
Arm Bridge Type
K Discontinuous
KP Armature Loop
KI Armature Loop
KP Field Loop
KI Field Loop
K Arm Volts
K AC Volts
Cur Desired BW
Cur Max BW
Cur Damp Factor
Bridge Switch Delay
K_Disc_fraction
Arm_Volt_Offset
Firmware Ver No.
SP Indirect 1
SP Indirect 2
SP Indirect 3
SP Indirect 4
SP Indirect 5
Trend Sign Val
Trend Sign Val
Trend Sign Val
Trend Sign Val
MIN
0
–32767
–32767
–16.0
0.0244
–6xB.S.
+6xB.S.
0
0.1
0.1
0
0
0
0.1
0
.2441
0
4
0
0
0
0
3000
2000
40
40
0.8
0
0.0
–20.0
0
–32767
–32767
–32767
–32767
–32767
–32767
–32767
–32767
–32767
MAX
32767
32767
32767
+16.0
260
0
+6xB.S.
B.S.
3276.7
3276.7
100
1.0
100
5.0
50.0
50.0
1
2048
32767
32767
32767
32767
25000
15000
1000
1000
3.0
75
0.9
20.0
32767
32767
32767
32767
32767
32767
32767
32767
32767
FUNCTION/CLASSIFICATION/PORT
Process Trim Control/Set-Up
Process Trim Control/Set-Up
Process Trim Control/Set-Up
Process Trim Control/Set-Up
Fault Detection/Set-Up
Process Trim Control/Setup
Process Trim Control/Set-Up
Process Trim Control/Set-Up
Fault Detection/Set-Up
Fault Detection/Set-Up
Fault Detection/Set-Up
Fault Detection/Set-Up
Fault Detection/Set-Up
Fault Detection/Set-Up
Fault Detection/Set-Up
Fault Detection/Set-Up
Auto Tuning Setup/Basic
Current PI Control/Autotune
Current PI Control/Autotune
Current PI Control/Autotune
Field PI Control/Set-Up
Field PI Control/Set-Up
Feedback Control/Basic
Feedback Control/Basic
AutoTuning Setup/Autotune
AutoTuning Setup/Autotune
AutoTuning Setup/Autotune
Basic
Current PI Control/Autotune
Basic
SP Control/Configuration
SP Control/Configuration
SP Control/Configuration
SP Control/Configuration
SP Control/Configuration
Trend Function
Trend Function
Trend Function
Trend Function
HEX
2CCH
2CDH
2CEH
2CFH
2D0H
2D1H
2D2H
2D4H
2D5H
2D6H
2D7H
2D8H
2D9H
2DAH
2DBH
2DCH
2DDH
2DEH
2DFH
2E0H
2E1H
2E2H
2E3H
2E4H
2E5H
2E6H
2E7H
2E8H
2E9H
2EAH
30CH
348H
349H
34AH
34BH
34CH
384H
385H
386H
387H
INIT
4096
–4096
4096
1.000
115
–6xB.S.
+6xB.S.
175
1.0
1.0
10.0
0.1
30
1.0
10.01
2.002
1
288
2330
386
16384
168
12500
7225
500
500
1.0
2
0.0
0.0
X.XX
0
0
0
0
0
0
0
0
0
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE