Rockwell Automation 1395 Digital DC Drive FRN 5-10.10/9.30 User Manual
Page 208

Chapter 7
Programming Parameters
7-42
Parameter 634 – Preset Speed 2 [Preset Speed 2]
Internal units : 4096 = 1000h = 1 PU = base motor speed
Programming Terminal units: RPM
Minimum Value: – 6 x base speed
Maximum Value: +6 x base speed
Default Value: 0
Description: This will be the velocity reference used by the drive
when
preset 2 has been selected in the logic command word.
Parameter 635 – Preset Speed 3 [Preset Speed 3]
Internal units : 4096 = 1000h = 1 PU = base motor speed
Programming Terminal units: RPM
Minimum Value: – 6 x base speed
Maximum Value: +6 x base speed
Default Value: 0
Description: This will be the velocity reference used by the drive
when preset 3 has been selected in the logic command word.
Parameter 636 – Preset Speed 4 [Preset Speed 4]
Internal units : 4096 = 1000h = 1 PU = base motor speed
Programming Terminal units: RPM
Minimum Value: – 6 x base speed
Maximum Value: +6 x base speed
Default Value: 0
Description: This will be the velocity reference used by the drive
when preset 4 has been selected in the logic command word.
Parameter 637 – Preset Speed 5 [Preset Speed 5]
Internal units : 4096 = 1000h = 1 PU = base motor speed
Programming Terminal units: RPM
Minimum Value: – 6 x base speed
Maximum Value: +6 x base speed
Default Value: 0
Description: This will be the velocity reference used by the Drive
when preset 5 has been selected in the logic command word.
Parameter 638 – Jog 1 Speed [Jog 1 Speed]
Internal units : 4096 = 1000h = 1 PU = base motor speed
Programming Terminal units: RPM
Minimum Value: – 6 x base speed
Maximum Value: +6 x base speed
Default Value: 0
Description: This will be the velocity reference used by the Drive
when Jog 1 has been selected in the logic command word.