ETC Eos Titanium, Eos, and Gio v2.0.0 User Manual
Page 119

6
Patch
101
• {Address} - A required entry field for any device. You may use the either the [At] or [Address/
Patch] key instead of the {Address} button.
•
Use the keypad to define the starting address for the device (from 1 to 65536) or a port
and offset value.
•
You may enter a start address without defining an end address. Eos will draw this
information from the library data. If you wish to leave a larger output gap than required
by the library, use [Offset]. See
Using {Offset} in Patch, page 90
.
•
If you specify a start address that conflicts with other channels already patched, the
conflicting channels will be unpatched after a confirmation is provided by the user.
• {Interface} - An optional field used to specify what network interfaces should be used for the
output. When the field is left blank, the default data output is used as selected in the
{Network} and {Local I/O} sections of the ECU. For more information about setting defaults
see
and
Local I/O (Eos Ti and Gio Only), page 382
. The interface
options available are sACN, Net 2- EDMX, ArtNet, Avab UDP, and Local DMX, depending on
what has been enabled in the {Network} and {Local I/O} sections of the ECU for the desk.
If an output option is not enabled, it will not appear in the {Interface} list.
• {Flash} - will bring a channel or address to full, and then every other second the level will
move to 15%. That will hold for 1 second, and then the level will return to full. The channel or
address will keep flashing until either the command line is cleared or {Flash} is selected
again.