Displaying layer 3 system parameter limits – Brocade Communications Systems Layer 3 Routing Configuration ICX 6650 User Manual
Page 153

Brocade ICX 6650 Layer 3 Routing Configuration Guide
135
53-1002603-01
Modifying and displaying Layer 3 system parameter limits
The Layer 3 system parameter limits for IPv6 models are automatically adjusted by the system and
cannot be manually modified.
Displaying Layer 3 system parameter limits
To display the Layer 3 system parameter defaults, maximum values, and current values, enter the
show default value command at any level of the CLI.
The following example shows the output on a Brocade ICX 6650 device.
Brocade#show default value
sys log buffers:50 mac age time:300 sec telnet sessions:5
ip arp age:10 min bootp relay max hops:4 ip ttl:64 hops
ip addr per intf:24
when multicast enabled :
igmp group memb.:260 sec igmp query:125 sec hardware drop: enabled
when ospf enabled :
ospf dead:40 sec ospf hello:10 sec ospf retrans:5 sec
ospf transit delay:1 sec
when bgp enabled :
bgp local pref.:100 bgp keep alive:60 sec bgp hold:180 sec
bgp metric:10 bgp local as:1 bgp cluster id:0
bgp ext. distance:20 bgp int. distance:200 bgp local distance:200
System Parameters Default Maximum Current
ip-arp 4000 64000 64000
ip-static-arp 512 6000 6000
multicast-route 64 8192 8192