beautypg.com

Send the stable result in basic unit, Send the result immediately in basic unit, Notice: use dots as decimal points in tare values – RADWAG WLY Scales User Manual

Page 186: Syntax: s cr lf, Possible answers, Frame format, Syntax: si cr lf

background image

186

Notice:
Use dots as decimal points in tare values.

34.4.5. Send the stable result in basic unit

Syntax: S CR LF

Possible answers:

S_A CR LF
S_E CR LF

- command accepted and in progress

- time limit for stable result exceeded

S_I CR LF

- command comprehended but cannot be executed

S_A CR LF
MASS FRAME

- command accepted and in progress

- mass value in basic unit is returned


Frame format:

1

2-3

4

5

6

7-15

16

17

18

19

20

21

S

space

stability

space

sign

mass

space

unit

CR

LF

Example:

S CR LF

– computer command

S _ A CR LF

- command accepted and in progress

S _ _ _ _ - _ _ _ _ _ _ 8 . 5 _ g _ _ CR LF

– command done, mass value

in basic unit is returned.

34.4.6. Send the result immediately in basic unit

Syntax: SI CR LF

Possible answers:

SI_I CR LF

- command comprehended but cannot be executed at the moment

MASS FRAME

- mass value in basic unit is returned


Frame format:

1

2

3

4

5

6

7-15

16

17

18

19

20

21

S

I

space

stability

space

sign

mass

space

unit

CR

LF

This manual is related to the following products: