beautypg.com

Festo Контроллеры двигателя SFC-LAC User Manual

Page 227

background image

B. Supplementary information

B−65

Festo GDCP−SFC−LACI−IO−EN en 0812NH

Homing method

CI

6098h

00h

Var

uint8

rw

Description

Reference travel (homing) method.
Values

Function

1 (0x01):

Search for limit switch in negative direction with index search

2 (0x02):

Search for limit switch in positive direction with index search

7 (0x07):

Search for reference switch in positive direction with index search

11 (0x0B):

Search for reference switch in negative direction with index search

−18 (0xEE): Search for stop in positive direction
−17 (0xEF): Search for stop in negative direction
The drive is no longer referenced after the reference travel (homing) method
has been modified.

Homing velocities

CI

6099h

01h...02h

Array

int32

rw

Description

Speeds during reference travel

Search REF

(search for REF)

01h

(search for REF)

Speed when searching for the reference point REF in [inc/s]

Search AZ

(search for AZ)

02h

(search for AZ)

Speed of travel to the axis zero point AZ in [inc/s]

Max. acceleration

CI

60C5h

00h

Var

uint32

r

Description

Max. permitted acceleration in [Inc/s

2

]