Festo Контроллеры двигателя SFC-LAC User Manual
Page 185

B. Supplementary information
B−23
Festo GDCP−SFC−LACI−IO−EN en 0812NH
Commutation status
CI
2050h
00h
Var
uint8
r
Description
State of the commutation point search
0x00: No commutation (default)
0x01: Commutation point search active
0x10: Commutation point successfully found
0xFE: Fault in commutation (POSITION PLAUSIBILITY ERROR)
0xFF: Fault in commutation (COMMUTATION POINT ERROR)
Delay for commutation start
CI
2051h
00h
Var
uint32
rw
Description
Waiting time [ms] between ENABLE and the start of the commutation point search.
Default = 0 ms.
During the search for the commutation point the drive vibrates. If several drives are
fitted in a system which can vibrate and if the search for the commutation point is
made at the same time, it may happen that the vibrations are superimposed and
the complete system vibrates in an uncontrolled manner. The drives cannot then
complete the search for the commutation point successfully.
·
In this case, start the search for the commutation point at staggered intervals:
ć by enabling the drives at staggered intervals via the PLC/IPC or
ć via this object.
FHPP version
CI
2066h
00h
Var
uint16
r
Description
Version number of FHPP in BCD (binary coded decimals): xxyy
(xx = main version, yy = secondary version)
Version FCT plug−in min.
CI
2067h
00h
Var
V−string
r
Description
Minimum FCT plug−in version required.
Format = xx.yy" (xx = main version, yy = secondary version)