beautypg.com

Festo Контроллеры двигателя SFC-LAC User Manual

Page 113

background image

5. Commissioning

5−31

Festo GDCP−SFC−LACI−IO−EN en 0812NH

MC: O1

Motion Complete

Output

Status

MC (output)

O1

Logic 0

Ĉ Positioning procedure is being carried

out.

Ĉ There is an error (if ERR = 0).

Logic 1

Ĉ Positioning procedure complete (actual

position is within the target window,
see CI object 6067

h

), or

Ĉ Nominal position = actual position (if no

enable set).

READY: O2

Ready for operation, all preconditions for starting a positionĆ
ing procedure have been met.

Output

Status

READY (output)

O2

Logic 0

System is not ready to operate.
Ĉ Logic 0 is active at ENABLE or
Ĉ there is an error or
Ĉ logic 0 is active at STOP.

Logic 1

System is ready for operation.
Ĉ Logic 1 is active at ENABLE and
Ĉ there is no error and
Ĉ logic 1 is active at STOP.