Festo Контроллеры двигателя SFC-LAC User Manual
Page 152

6. Diagnostics and error display
6−12
Festo GDCP−SFC−LACI−IO−EN en 0812NH
Error
Fault
no.
*)
Object
Possible cause and remedy
DIGITAL−POWER−
DOWN
Logic voltage < 15 V
Ĉ Voltage drops under load: Power supply too weak,
cable too long, cable cross−section too small?
2FF1h
Bit 6
71
OVERCURRENT
POWER STAGE
Output stage current consumption too high, e.Ăg. due
to short circuit.
·
Contact Festo service.
2FFBh
Bit 1
72
ERROR SFC−LACI
HOT
Temperature >āā 85 °C
·
Remain within all maximum values and check the
mechanical system, e.Ăg. for sluggishness.
·
Reduce the ambient temperature.
·
Improve the heat dissipation.
2FF1h
Bit 5
73
ELGO SENSOR /
COMMUNICATION
ERROR
Position sensor faulty
·
Contact Festo service.
2FF1h
Bit 2
82
CAN
COMMUNICATION
ERROR
CAN communication fault
·
Contact Festo service.
2FF1h
Bit 1
83
i
2
t−ERROR
Current monitoring i
2
t
Possible cause: The drive is blocked, load/dynamics
too high.
·
Check the drive mechanics.
·
Reduce load/dynamic response; increase the
pause times.
2FF1h
Bit 12
100
ERROR MOTOR
HOT
Temperature of the linear motor >āā 75 °C
·
Remain within all maximum values and check the
mechanical system, e.Ăg. for sluggishness.
·
Reduce the ambient temperature.
·
Improve the heat dissipation.
2FF1h
Bit 4
101
MOTOR STOP
ERROR
The positioning procedure is discontinued on the conĆ
trol panel with EMERG.STOP (