Chapter 7: Second Level Commands

June 30, 2006

7-16

SG1-UM-8500-03

The port number to be designated as the protect port (valid value = 1 or 2).

[SFBER (value)]

Signal Fail Bit Error Rate Threshold. Valid values = 3 to 12, Default = 3.

[SDBER (value)]

Signal Degrade Bit Error Rate Threshold. Valid values = 5 to 12, Default = 5.

Example(s)

Configuring OC3 interfaces

Usage

interface atm \ [type

multipoint| ip |

point>(ip |loopback )|mtu <(1500|1544)>]

Parameter(s)

The value 2 is required to select the SONET/SDH interface.

Use value 1 or 2 to select port 1 or 2.

A logical interface number from 1 to 2000.

[type ]

The ppp represents PPP termination.

[type ip ]

The routed parameter implies routing capability only.

[type ]

The bridge-route parameter implies bridge and routing capabilities.

IP address for the interface to be configured.

Valid mask for the associated IP address.

Host(config)# port sonet redundancy-enable 2 \ 1 \ 2 \ 2 SFBER 3 SDBER 5

Updated item

Host(config)#

Host(config)# interface