Assigning a pager code to a subsystem controller – HP StorageWorks 3000 RAID Array User Manual
Page 95
Using Command Console 3-49
Compaq Confidential – Need to Know Required
Writer: Bob Young Project: Command Console V2.2 for the RAID Array 3000 (Pedestal and Rack Mount Models) User’s Guide Comments:
Part Number: AA-RBF2C-TE File Name: d-ch3 Using Command Console.doc Last Saved On: 12/5/00 10:20 AM
Assigning a Pager Code to a Subsystem Controller
1.
Click a subsystem controller in the Navigation window.
2.
From the File menu, click Properties.
3.
Click the Event Notification tab.
4.
Enter a three-digit number in the Pager Identification Number text box.
Viewing and Changing a Pager Critical Event
Code
1.
From the Options menu, click Event Notification Pager Codes.
2.
Click the code you want to edit, then select Edit.
3.
Type the new four-digit pager code in the text box. The default codes
are shown in Table 3-1.
Table 3-1
Pager Critical Event Codes
Critical Event
Code
Description
Disk fault
1000
Physical device failure
Power supply fault
1001
Fan fault
1002
Battery fault
1003
Temperature fault
1004
Controller fault
1005
Controller has detected internal fault.
Communication fault
1006
Agent cannot communicate with
subsystem.
Other Controller fault
1007
One controller is reporting a fault on other
controller.
External fault
1008
LUN fault
1009
Virtual disk failure