Performing basic configuration tasks

To set the time zone:

1.

Connect to the switch and log in as admin.

2.

Issue the

tstimezone

command as follows:

tstimezone [houroffset [, minuteoffset]]

• For Pacific Standard Time enter

tsTimeZone -8,0

• For Central Standard Time enter

tsTimeZone -6,0

• For Eastern Standard Time enter

tsTimeZone -5,0

The default time zone for switches is Universal Time Conversion (UTC), which is 8 hours ahead of

(later than) Pacific Standard Time (PST). For additional time zone conversions, see

Table 3

.

The parameters do not apply if the time zone of the switch has already been changed from the default

(8 hours ahead of PST).

Refer to the

tstimezone

command in the HP StorageWorks Fabric OS 4.x command reference

guide for more detailed information about the command parameters.

3.

Repeat the procedure on all switches for which the Time Zone needs to be set. This needs to be done

only once, because the value is written to nonvolatile memory.

For U.S. time zones, use

Table 3

to determine the correct parameter for the

tstimezone

command.

Table 3

Conversion from UTC to local time

Local time

tstimezone conversion

parameter

Atlantic Standard

-4,0

Atlantic Daylight

-3,0

Eastern Standard

-5,0

Eastern Daylight

-4,0

Central Standard

-6,0

Central Daylight

-5,0

Mountain Standard

-7,0

Mountain Daylight

-6,0

Pacific Standard

-8,0

Pacific Daylight

-7,0

Alaskan Standard

-9,0

Alaskan Daylight

-8,0

Hawaiian Standard

-10,0