beautypg.com

Configuring interoperability mode, Vendor switch requirements, Hp storageworks switch requirements – HP Brocade 4Gb SAN Switch for HP BladeSystem p-Class User Manual

Page 219: B configuring interoperability mode

background image

Fabric OS 5.0.0 procedures user guide 219

B Configuring interoperability mode

This appendix contains the following sections:

Vendor switch requirements

, page 219

HP StorageWorks switch requirements

, page 219

Supported HP StorageWorks features

, page 220

Unsupported HP StorageWorks features

, page 220

Configuration recommendations

, page 221

Configuration restrictions

, page 221

Enabling and disabling interoperability mode

, page 222

This appendix provides information on setting up a heterogeneous fabric that includes HP StorageWorks

switches and switches from other manufacturers.

The interoperability mode enables HP StorageWorks switches and others to exchange interoperability

parameters, allowing their fabrics to merge into one fabric with one principal switch and unique

domain IDs.

The

interopmode

command must be executed on all HP StorageWorks switches in the fabric. Each HP

StorageWorks switch must be rebooted after changing interoperability mode.

Switches from other manufacturers may also require the execution of one or more commands to set up

interoperability mode. Refer to their documentation for details.

In a heterogeneous fabric, each HP StorageWorks switch must have interoperability mode enabled (see

Enabling and disabling interoperability mode

” on page 222).

To provide maximum compatibility between switches, several features are not available in heterogeneous

fabrics (see

Supported HP StorageWorks features

” on page 220 and ”

Unsupported HP StorageWorks

features

” on page 220).

Vendor switch requirements

To determine whether or not a mixed-vendor SAN is supported, work with the switch provider to

determine if your SAN design is valid. Important variables that determine the supportability of a

particular mixed vendor SAN include the number of switches, version of Fabric OS, the topology, number

of ISLs, number of connected devices, and hop count. For interoperability rules, refer to HP StorageWorks

SAN design reference guide.

HP StorageWorks switch requirements

The following are the HP StorageWorks software requirements:

1 GB switches must be running Fabric OS v2.6.0 or later.

2 GB switches must be running Fabric OS v3.1.0 or later.