Brocade 4gb san switch for hp p-class bladesystem, About procedural differences – HP Brocade 4Gb SAN Switch for HP BladeSystem p-Class User Manual
Page 15
Fabric OS 5.0.0 procedures user guide
15
•
On page 108, in the section “Choosing an extended ISL mode,” add the following:
Brocade 4Gb SAN Switch for HP p-Class BladeSystem
The number of ports that can be configured at various distances is summarized in
.
•
On page 146, in the section “Adding end-to-end monitors,” change the following paragraph:
The HP StorageWorks SAN Switch 2/8V, SAN Switch 2/16V, SAN Switch 2/32, Core Switch
2/64, SAN Director 2/128, allow up to eight end-to-end monitors allow up to eight end-to-end
monitors.
to:
The HP StorageWorks SAN Switch 2/8V, SAN Switch 2/16V, SAN Switch 2/32, Core Switch
2/64, SAN Director 2/128, and Brocade 4Gb SAN Switch for HP p-Class BladeSystem allow up
to eight end-to-end monitors.
•
On page 149, in the section “Monitoring filter-based performance,” change the following
paragraph:
For HP StorageWorks SAN Switch 2/8V, SAN Switch 2/16V, SAN Switch 2/32, Core Switch
2/64, and SAN Director 2/128, the maximum number of filters is eight per port, in any
combination of standard filters and user-defined filters.
to:
For HP StorageWorks SAN Switch 2/8V, SAN Switch 2/16V, SAN Switch 2/32, Core Switch
2/64, SAN Director 2/128, and Brocade 4Gb SAN Switch for HP p-Class BladeSystem, the
maximum number of filters is eight per port, in any combination of standard filters and
user-defined filters.
•
On page 219, in the section “HP StorageWorks switch requirements,” add the following:
Brocade 4Gb SAN Switch for HP p-Class BladeSystem running Fabric OS 5.0.0 or later.
About procedural differences
As a result of the differences between fixed-port and variable-port devices, procedures sometimes differ
between HP StorageWorks switch models. Also, because the domain architecture of the Core Switch
2/64 differs from that of the SAN Director 2/128, there are sometimes procedural differences between
these two.
When procedures or parts of procedures apply to some models but not others, this guide identifies the
specifics for each model. For example, a number of procedures that apply only to variable-port devices
are found in ”
Configuring the Core Switch 2/64 and the SAN Director 2/128
” on page 89. Procedures
that apply only to the SAN Switch 4/32 are labeled as such.
Table 2
Brocade 4Gb SAN Switch for HP p-Class BladeSystem
Speed
(Gbit/sec)
Number of ports allowed at distance (km)
1 2 3 4
1
286
154
110
88
2
143
77
55
44
4
71.5
38.5
27.5
22