166 Working with diagnostic features

POST1 cannot be bypassed; it runs from the boot loader. The factory default configuration is also set to

run POST2, but you can configure your switch to bypass POST2, which runs after the kernel image has

started but before general system services, such as login, are enabled.

Although each test performed during POST2 is configurable, modify a POST2 test only if directed by your

switch provider’s customer service representative.

You can use the

diagdisablepost

command to disable POST2, and you can reenable it using the

diagenablepost

command. Refer to the HP StorageWorks Fabric OS 4.x command reference guide

for additional information about these commands.

The following example shows a typical boot sequence, including POST messages:

If you choose to bypass POST2, or after POST2 completes, various system services are started and the

boot process displays additional console status and progress messages.

Viewing switch status

Use the

switchstatusshow

command to display the overall status of the switch, including its power

supplies, fans, and temperature. If the status of any one of these components is either marginal or down,

the overall status of the switch is also displayed as marginal or down. If all components have a healthy

status, the switch displays a healthy status.

The rules used to classify the health of each component are in the configuration files. To change the rules,

you must use the

configupload

command to copy the configuration files, edit them manually, and use

the

configdownload

command to load them back to the switch.

To view the overall status of the switch:

1.

Connect to the switch and log in as admin.

***********************************************************************
***

* Copyright (c) 2004, *

* Switchname *

* Firmware Version 4.x.x.x.H build #XX: Sat Jan 31 12:40:41 PDT 2004

* MAC Address: 00:05:1E:31:2F:60

* BCSR FPGA Version 2007

*

***********************************************************************
***

Power-on Self Test

1024 MB SDRAM installed

Executing code from SDRAM at 0203B5E0

Power supply 1 status test PASSED

Power supply 2 status test FAILED

Fan tray status 1 test PASSED

Fan tray status 2 test PASSED

SEPROM initialized. SEPROM test is BYPASSED

Dram test #2 is BYPASSED

Compact Flash is installed

Autoboot command: “memboot”

Press to execute or any other key to abort.