Correcting link failures – HP Brocade 4Gb SAN Switch for HP BladeSystem p-Class User Manual
Page 196
196 Troubleshooting
Correcting link failures
A link failure occurs when a server or storage is connected to a switch, but the link between the
server/storage and the switch does not come up. This prevents the server/storage from communicating
through the switch.
If the
switchshow
command and/or the LEDs indicate that the link has not come up properly, use one or
more of the following procedures.
To determine if the negotiation was successfully completed:
The port negotiates the link speed with the opposite side. The negotiation usually completes in 1-2
seconds; however, sometimes the speed negotiation fails.
NOTE:
Skip this procedure if the port speed is set to a static speed through the
portCfgSpeed
command.
1.
Issue the switchshow command to determine the speed of the device.
2.
Issue the
portLogShow
or
portLogDump
command.
3.
Check the events area of the output. The first example is 1 Gbps and the second example is 2 Gbps:
• The
sn
field indicates a speed negotiation.
• The
NC
field indicates Negotiation Complete.
• The
01
or
02
fields indicate the speed that has been negotiated.
If these fields do not appear, proceed to the
4.
Correct the negotiation by entering the
portCfgSpeed
[slotnumber/]portnumber,
speed_level
command if the fields in
do not appear.
turboramtest
Verifies that the on chip SRAM located in the 2 Gbps ASIC is using the
Turbo-Ram BIST circuitry. These same SRAMs are tested by
portregtest
and
sramretentiontest
using PCI operations, but
for this test the BIST controller is able to perform the SRAM write and
read operations at a much faster rate.
statstest
Verifies that the ASIC statistics counter logic.
Related Switch Test Command:
itemlist
Restricts the items to be tested to a smaller set of parameter values that
you pass to the switch.
Table 33
Switch component tests (continued)
Test
Function