To download a correct configuration, To reconcile a domain id conflict, Correcting zoning setup issues – HP Brocade 4Gb SAN Switch for HP BladeSystem p-Class User Manual

Page 187: Table 30 types of zone discrepancies, 30 types of zone discrepancies

background image

Fabric OS 5.0.0 procedures user guide 187

8.

Issue the

configure

command to edit the fabric parameters for the segmented switch.

Refer to the HP StorageWorks Fabric OS 4.x command reference guide for more detailed

information.

9.

Enable the switch by entering the

switchenable

command.

To download a correct configuration:
You can restore a segmented fabric by downloading a previously saved correct backup configuration to

the switch. Downloading in this manner reconciles any discrepancy in the fabric parameters and allows

the segmented switch to rejoin the main fabric. For details on uploading and downloading

configurations, see

Maintaining configurations

” on page 75.

To reconcile a domain ID conflict:
If a domain ID conflict appears, the conflict is only reported at the point where the two fabrics are

physically connected. However, there might be several conflicting domain IDs, which appear as soon as

the initial conflict is resolved.

Repeat this procedures until all domain ID conflicts are resolved:

1.

Issue the

switchshow

command on a switch from one of the fabrics.

2.

Open a separate telnet window.

3.

Issue the

switchshow

command on a switch from the second fabric.

4.

Compare the

switchshow

output from the two fabrics. Note the number of domain ID conflicts; there

might be several duplicate domain IDs that need to be changed.

5.

Chose the fabric on which to change the duplicate domain ID; connect to the conflicting switch in that

fabric.

6.

Issue the

switchdisable

command.

7.

Issue the

switchenable

command.

This enables the joining switch to obtain a new domain ID as part of the process of coming online.

The fabric principal switch allocates the next available domain ID to the new switch during this

process.

8.

Repeat

step 5

through

step 7

if additional switches have conflicting domain IDs.

Correcting zoning setup issues

The types of zone configuration discrepancies that can cause segmentation are listed in

Table 30

.

Table 30

Types of zone discrepancies

Conflict cause

Description

Configuration

mismatch

Occurs when zoning is enabled in both fabrics and the zone

configurations that are enabled are different in each fabric.

Type mismatch

Occurs when the name of a zone object in one fabric is also used for a

different type of zone object in the other fabric. A zone object is any

device in a zone.

Content mismatch

Occurs when the definition of a in one fabric is different from the

definition of a zone object with the same name in the other fabric.