HP Brocade 4Gb SAN Switch for HP BladeSystem p-Class User Manual
Page 103
Fabric OS 5.0.0 procedures user guide 103
Example:
3.
Issue the
urouteshow
command to display unicast routing information.
For the HP StorageWorks SAN Switch 2/8V, SAN Switch 2/16V, SAN Switch 2/32, and SAN
Switch 4/32, use the following syntax:
urouteshow
[portnumber][, domainnumber]
For the Core Switch 2/64 and the SAN Director 2/128, use the following syntax:
urouteshow
[slot/][portnumber][, domainnumber]
The following entries appear:
switch:admin> topologyshow
2 domains in the fabric; Local Domain ID: 1
Domain: 6
Metric: 500
Name: switch
Path Count: 4
Hops: 1
Out Port: 60
In Ports: None
Total Bandwidth: 2 Gbps
Bandwidth Demand: 0%
Flags: D
Hops: 1
Out Port: 61
In Ports: None
Total Bandwidth: 2 Gbps
Bandwidth Demand: 0%
Flags: D
Hops: 1
Out Port: 62
In Ports: None
Total Bandwidth: 2 Gbps
Bandwidth Demand: 0%
Flags: D
Hops: 1
Out Port: 58
In Ports: None
Total Bandwidth: 2 Gbps
Bandwidth Demand: 0%
Flags: D
•
Local Domain
Domain number of local switch
•
In Ports
Port from which a frame is received
•
Domain
Destination domain of incoming frame
•
Out Port
The port that incoming frame is forwarded to, in order to reach
the destination domain
•
Metric
Cost of reaching destination domain
•
Hops
The maximum number of hops to reach destination domain
•
Flags
Indicates whether route is dynamic (D) or static (S). A static
route is assigned using the command
urouteconfig
•
Next (Dom, Port)
Domain and port number of the next hop. These are the
domain number and the port