beautypg.com

HP Brocade 4Gb SAN Switch for HP BladeSystem p-Class User Manual

Page 103

background image

Fabric OS 5.0.0 procedures user guide 103

Example:

3.

Issue the

urouteshow

command to display unicast routing information.

For the HP StorageWorks SAN Switch 2/8V, SAN Switch 2/16V, SAN Switch 2/32, and SAN

Switch 4/32, use the following syntax:

urouteshow

[portnumber][, domainnumber]

For the Core Switch 2/64 and the SAN Director 2/128, use the following syntax:

urouteshow

[slot/][portnumber][, domainnumber]

The following entries appear:

switch:admin> topologyshow

2 domains in the fabric; Local Domain ID: 1

Domain: 6

Metric: 500

Name: switch

Path Count: 4

Hops: 1

Out Port: 60

In Ports: None

Total Bandwidth: 2 Gbps

Bandwidth Demand: 0%

Flags: D

Hops: 1

Out Port: 61

In Ports: None

Total Bandwidth: 2 Gbps

Bandwidth Demand: 0%

Flags: D

Hops: 1

Out Port: 62

In Ports: None

Total Bandwidth: 2 Gbps

Bandwidth Demand: 0%

Flags: D

Hops: 1

Out Port: 58

In Ports: None

Total Bandwidth: 2 Gbps

Bandwidth Demand: 0%

Flags: D

Local Domain

Domain number of local switch

In Ports

Port from which a frame is received

Domain

Destination domain of incoming frame

Out Port

The port that incoming frame is forwarded to, in order to reach

the destination domain

Metric

Cost of reaching destination domain

Hops

The maximum number of hops to reach destination domain

Flags

Indicates whether route is dynamic (D) or static (S). A static

route is assigned using the command

urouteconfig

Next (Dom, Port)

Domain and port number of the next hop. These are the

domain number and the port